In message <[log in to unmask]>,
Mohammad Al-Jubouri <[log in to unmask]> writes
> Dear All
>
> The cut off TnT level for diagnosis of acute MI is set at > 1 ug/L
> by BCS without reference to timing of the sample post-event. This
> is certainly a high level as we certainly have seen cases of acute
> MI below this cut off.
> Could it be a typo error i.e > 0.1 ug/L, what are the views of list
> members?
>
> regards
>
> Mohammad
>
>
> Dr. M A Al-Jubouri
> Consultant Chemical Pathologist
>
> ALL-NEW Yahoo! Messenger - all new features - even more fun!
> ------ACB discussion List Information-------- This is an open
> discussion list for the academic and clinical community working in
> clinical biochemistry. Please note, archived messages are public
> and can be viewed via the internet. Views expressed are those of
> the individual and they are responsible for all message content.
>
> ACB Web Site http://www.acb.org.uk List Archives
> http://www.jiscmail.ac.uk/lists/ACB-CLIN-CHEM-GEN.html List
> Instructions (How to leave etc.) http://www.jiscmail.ac.uk/
The value is much to high
It should be 0.05
--
Paul Collinson
------ACB discussion List Information--------
This is an open discussion list for the academic and clinical
community working in clinical biochemistry.
Please note, archived messages are public and can be viewed
via the internet. Views expressed are those of the individual and
they are responsible for all message content.
ACB Web Site
http://www.acb.org.uk
List Archives
http://www.jiscmail.ac.uk/lists/ACB-CLIN-CHEM-GEN.html
List Instructions (How to leave etc.)
http://www.jiscmail.ac.uk/
|