Hello,
The answer is yes to both questions - the min/max controls the colours assigned to the voxel values, which in this case are ( 1-p) values. So a range of 0.95 to 1, will assign the full colour range to voxels with significant values, will a range of 0 to 1 will assign the full colour range across the range of all possible p-values.
Hope this helps,
Kind regards
matthew
> On 12 Jul 2016, at 09:41, Kavita Singh <[log in to unmask]> wrote:
>
> Hi all,
> Kindly excuse me if its obvious. Does min/max on top of image relate to p-value when we open tbss_tfce_corrp_tstat files? Is it just the range for colour we choose?
> I am trying to open tbss_tfce_corrp_tstat document, where 0.95 (min) and 1.0 (max) doesnot show any result however changing the minimum value to 0.58 displays many clusters. All the more, now both tstat1 and tstat2 shows clusters.
>