Yes, this is possible using the Montage function. See the manual
section 36.1.2 p. 353.
Vladimir
On Mon, Oct 25, 2010 at 5:50 PM, Michael Spezio
<[log in to unmask]> wrote:
> I'd like to use EGI's specification of HEOG channels (61 & 64) and VEOG
> channels (L: 10 & 63; R: 5 & 62) to calculate difference channels for
> eyeblink and movement artifact rejection.
>
> Is this possible within SPM8? Can one create new channels such as these
> difference channels?
>
> Best,
>
> Michael
>
> Michael L. Spezio, Ph.D.
> Assistant Professor of Psychology
> Department of Psychology
> Scripps College
> Claremont, CA
> [log in to unmask]
> 909.607.0914
>
> and
>
> Visiting Associate Scientist
> Psychology & Neuroscience
> Division of Humanities & Social Sciences
> Caltech
> Pasadena, CA 91125
> [log in to unmask]
>
|