What are your acquisition parameters (Resolution, TR, number of minutes)? How did you preprocess the data? When using the HCP training file, it assumes your data meets HCP acquisition standards and was processed with the HCP Pipelines.
Matt.
On 6/16/20, 5:50 AM, "FSL - FMRIB's Software Library on behalf of Neeraj Upadhyay" <[log in to unmask] on behalf of [log in to unmask]> wrote:
* External Email - Caution *
I am applying Fix for automated ICA removal from my multiband resting fMRI data. after applying,There was no noise components were present in the last row of the fslfix_melview_thr.txt file even with different training sets included( Standard.Rdata, HCP, WII etc).
There was no error report either in the log_matlab files inside the fix folder.
Please help me in sorting out this problem.
the output of the fix4melview_Standard_thr10.txt file is as follows:
filtered_func_data.ica
1, Signal, False,0.612
2, Signal, False,0.652
3, Signal, False,0.626
4, Signal, False,0.576
5, Signal, False,0.612
6, Signal, False,0.534
7, Signal, False,0.588
8, Signal, False,0.53
9, Signal, False,0.646
10, Signal, False,0.554
11, Signal, False,0.552
12, Unknown, False,0.428
13, Unknown, False,0.42
14, Signal, False,0.52
15, Signal, False,0.534
16, Unknown, False,0.47
17, Signal, False,0.52
18, Signal, False,0.526
19, Unknown, False,0.276
20, Signal, False,0.58
21, Unknown, False,0.328
22, Unknown, False,0.424
23, Signal, False,0.614
24, Signal, False,0.654
25, Signal, False,0.552
26, Signal, False,0.502
27, Signal, False,0.506
28, Unknown, False,0.412
29, Unknown, False,0.458
30, Unknown, False,0.39
31, Signal, False,0.534
32, Signal, False,0.514
33, Signal, False,0.556
34, Signal, False,0.638
35, Unknown, False,0.292
36, Unknown, False,0.45
37, Signal, False,0.562
38, Signal, False,0.556
39, Signal, False,0.566
40, Unknown, False,0.48
41, Unknown, False,0.292
42, Unknown, False,0.46
43, Unknown, False,0.424
44, Signal, False,0.524
45, Unknown, False,0.478
46, Signal, False,0.626
47, Unknown, False,0.42
48, Signal, False,0.648
49, Signal, False,0.646
50, Signal, False,0.53
51, Signal, False,0.608
52, Unknown, False,0.498
53, Unknown, False,0.454
54, Signal, False,0.512
55, Unknown, False,0.368
56, Signal, False,0.536
57, Unknown, False,0.492
58, Signal, False,0.538
59, Unknown, False,0.488
60, Unknown, False,0.462
61, Unknown, False,0.44
62, Unknown, False,0.46
63, Unknown, False,0.448
64, Unknown, False,0.442
65, Unknown, False,0.482
66, Unknown, False,0.456
67, Signal, False,0.524
68, Signal, False,0.562
69, Unknown, False,0.468
70, Unknown, False,0.44
71, Signal, False,0.53
72, Signal, False,0.566
73, Unknown, False,0.394
74, Signal, False,0.608
75, Unknown, False,0.494
76, Unknown, False,0.478
77, Signal, False,0.616
78, Unknown, False,0.486
[]
########################################################################
To unsubscribe from the FSL list, click the following link:
https://www.jiscmail.ac.uk/cgi-bin/WA-JISC.exe?SUBED1=FSL&A=1
This message was issued to members of www.jiscmail.ac.uk/FSL, a mailing list hosted by www.jiscmail.ac.uk, terms & conditions are available at https://www.jiscmail.ac.uk/policyandsecurity/
________________________________
The materials in this message are private and may contain Protected Healthcare Information or other information of a sensitive nature. If you are not the intended recipient, be advised that any unauthorized use, disclosure, copying or the taking of any action in reliance on the contents of this information is strictly prohibited. If you have received this email in error, please immediately notify the sender via telephone or return mail.
########################################################################
To unsubscribe from the FSL list, click the following link:
https://www.jiscmail.ac.uk/cgi-bin/WA-JISC.exe?SUBED1=FSL&A=1
This message was issued to members of www.jiscmail.ac.uk/FSL, a mailing list hosted by www.jiscmail.ac.uk, terms & conditions are available at https://www.jiscmail.ac.uk/policyandsecurity/
|