JiscMail Logo
Email discussion lists for the UK Education and Research communities

Help for CONTAMINATED-LAND-STRATEGIES Archives


CONTAMINATED-LAND-STRATEGIES Archives

CONTAMINATED-LAND-STRATEGIES Archives


CONTAMINATED-LAND-STRATEGIES@JISCMAIL.AC.UK


View:

Message:

[

First

|

Previous

|

Next

|

Last

]

By Topic:

[

First

|

Previous

|

Next

|

Last

]

By Author:

[

First

|

Previous

|

Next

|

Last

]

Font:

Proportional Font

LISTSERV Archives

LISTSERV Archives

CONTAMINATED-LAND-STRATEGIES Home

CONTAMINATED-LAND-STRATEGIES Home

CONTAMINATED-LAND-STRATEGIES  December 2017

CONTAMINATED-LAND-STRATEGIES December 2017

Options

Subscribe or Unsubscribe

Subscribe or Unsubscribe

Log In

Log In

Get Password

Get Password

Subject:

Re: Retrofitting Gas Protection Membrane

From:

Alex Wall <[log in to unmask]>

Reply-To:

Alex Wall <[log in to unmask]>

Date:

Fri, 1 Dec 2017 09:09:41 +0000

Content-Type:

text/plain

Parts/Attachments:

Parts/Attachments

text/plain (61 lines)

Hello,

Please see the responses which I received (providing for anonymity). My original query was:

I am currently looking at a site where a decision was made that a gas protection membrane had to be installed into a build when the works were significantly progressed. At this point in time the first floor had been erected so a methodology was drawn together to retrofit the membrane into the build. In short this involved propping up the first floor and cutting out the relevant blocks in the external and internal walls. The developer assures me that the NHBC will confirm that they are satisfied with the installation.

Is there any set guidance relating to this scenario? Has this been done elsewhere?

Responses:

1) 

Not sure what your exact circumstances are but they may have been better looking at some of the gas resistance epoxy paints / resins which are available - that way they wouldn’t have to pull up slabs and they may have benefited from installer warranties.

2)

If you can I would get in touch with your local NHBC counterpart for land contamination and make sure they are aware of the scheme. If you don’t know who they are I can ask my local counterpart for their details. 
 
I am about to have one of these retro-fitted schemes on a prior approval site and have insisted through planning that the installer has the CSkills NVQ Level 2 Gas Membrane Installation and have also requested independent validation of the installation.
 
Off the record the people who are undertaking the building works installed a membrane so poorly on a previous site, an active system had to be installed post completion – hence why I am asking for the above as I have concerns about their ability to undertake the works.  


3)

We had a site a few years (a couple of townhouses on an old gasworks) where a vapour membrane was required and this had to be done retrospectively as the developers just cracked on.  They did exactly as you said in your email in that they propped up the first floor and cut out the relevant blocks in the external and internal walls.  It was tricky but was done to our satisfaction and the NHBC.  As far as guidance for this scenario I am not sure if there is – I would though be interested to hear if you find out there is guidance on the subject.

4)

This is pretty much a last option so doesn’t tick any of the good practice guides. That being said, validation and verification is key.

We routinely do this where there has been a hydrocarbon spill adjacent to a building. Fairly straight forward if designed and verified.

5)

In X we had a similar issue with a commercial building which was substantially completed without the promised/conditioned gas protection measures (CS2). 

The consultant, who was actually quite good, attempted to negotiate a retro fit with his client and provided additional ventilation calculations etc. which demonstrated that the installation of additional ground floor wall cavity vents and ventilation vents under the roof eaves of the building would be sufficient to generate air flow through the building to reduce gas flow/accumulation to an acceptable level. The ventilation calculations are set out in the CIEH "LA-Guide to Ground-gas (c.2008)" and relate primary to car subfloor car parks but they seem robust for our needs. We also required that the measures were documented I the Site's Risk Management Register so that future owners and tenants would be made aware of the risk measures in place. 

It was very much a bodge job in a managed warehouse type building and not an approach I would advocate for a private residential dwelling - which is a much higher risk prospect!

I think attempting to retro fit a membrane will be fraught with difficulties with high risk of rips and poor seals. Whatever passes should be independently verified by suitably qualified person (CIRIA C735).

6)

I am not aware of any guidance but it has been done before.  It needs to be done very carefully but can be successful.  There are other options available as well to seal the cavity without taking the membrane through the wall - depends on slab and wall details and level of gas risk

7)

Retro fitting a gas membrane by jacking up the house sequentially taking out a course and fitting membrane across the cavity is possible but immensely expensive and fraught with difficulties. Depending on the risk profile I have seen sub floor monitoring, internal floor membranes and cavity testing and in the case of managed buildings active ventilation solutions all used to good effect. However if the developer has opted for this solution he has either tried these and failed or was not aware and has been led down a particular route.
The key, as in all gas solution installation, is validation and so long as there is an appropriately qualified independent validator involved who is essentially signing off the work ( this must be an amber 2 site ) then you can be confident the installation will be in line with standards and work. Beware there is a proliferation of unqualified validators signing off associated companies work; for your own peace of mind I would check the independence of the installer / validator relationship.

Thank you,

Mr Alex Wall
Technical Officer - Environmental Health
 
Quadrant, The Silverlink North, Cobalt Business Park, North Tyneside, NE27 0BY
Tel: 0191 643 6647
Email: [log in to unmask]

Top of Message | Previous Page | Permalink

JiscMail Tools


RSS Feeds and Sharing


Advanced Options


Archives

April 2024
March 2024
February 2024
January 2024
December 2023
November 2023
October 2023
September 2023
August 2023
July 2023
June 2023
May 2023
April 2023
March 2023
February 2023
January 2023
December 2022
November 2022
October 2022
September 2022
August 2022
July 2022
June 2022
May 2022
April 2022
March 2022
February 2022
January 2022
December 2021
November 2021
October 2021
September 2021
August 2021
July 2021
June 2021
May 2021
April 2021
March 2021
February 2021
January 2021
December 2020
November 2020
October 2020
September 2020
August 2020
July 2020
June 2020
May 2020
April 2020
March 2020
February 2020
January 2020
December 2019
November 2019
October 2019
September 2019
August 2019
July 2019
June 2019
May 2019
April 2019
March 2019
February 2019
January 2019
December 2018
November 2018
October 2018
September 2018
August 2018
July 2018
June 2018
May 2018
April 2018
March 2018
February 2018
January 2018
December 2017
November 2017
October 2017
September 2017
August 2017
July 2017
June 2017
May 2017
April 2017
March 2017
February 2017
January 2017
December 2016
November 2016
October 2016
September 2016
August 2016
July 2016
June 2016
May 2016
April 2016
March 2016
February 2016
January 2016
December 2015
November 2015
October 2015
September 2015
August 2015
July 2015
June 2015
May 2015
April 2015
March 2015
February 2015
January 2015
December 2014
November 2014
October 2014
September 2014
August 2014
July 2014
June 2014
May 2014
April 2014
March 2014
February 2014
January 2014
December 2013
November 2013
October 2013
September 2013
August 2013
July 2013
June 2013
May 2013
April 2013
March 2013
February 2013
January 2013
December 2012
November 2012
October 2012
September 2012
August 2012
July 2012
June 2012
May 2012
April 2012
March 2012
February 2012
January 2012
December 2011
November 2011
October 2011
September 2011
August 2011
July 2011
June 2011
May 2011
April 2011
March 2011
February 2011
January 2011
December 2010
November 2010
October 2010
September 2010
August 2010
July 2010
June 2010
May 2010
April 2010
March 2010
February 2010
January 2010
December 2009
November 2009
October 2009
September 2009
August 2009
July 2009
June 2009
May 2009
April 2009
March 2009
February 2009
January 2009
December 2008
November 2008
October 2008
September 2008
August 2008
July 2008
June 2008
May 2008
April 2008
March 2008
February 2008
January 2008
December 2007
November 2007
October 2007
September 2007
August 2007
July 2007
June 2007
May 2007
April 2007
March 2007
February 2007
January 2007
December 2006
November 2006
October 2006
September 2006
August 2006
July 2006
June 2006
May 2006
April 2006
March 2006
February 2006
January 2006
December 2005
November 2005
October 2005
September 2005
August 2005
July 2005
June 2005
May 2005
April 2005
March 2005
February 2005
January 2005
December 2004
November 2004
October 2004
September 2004
August 2004
July 2004
June 2004
May 2004
April 2004
March 2004
February 2004
January 2004
December 2003
November 2003
October 2003
September 2003
August 2003
July 2003
June 2003
May 2003
April 2003
March 2003
February 2003
January 2003
December 2002
November 2002
October 2002
September 2002
August 2002
July 2002
June 2002
May 2002
April 2002
March 2002
February 2002
January 2002
December 2001
November 2001
October 2001
September 2001
August 2001
July 2001
June 2001
May 2001
April 2001
March 2001
February 2001
January 2001
December 2000
November 2000
October 2000
September 2000
August 2000
July 2000
June 2000
May 2000
April 2000
March 2000
February 2000
November 1999
July 1999


JiscMail is a Jisc service.

View our service policies at https://www.jiscmail.ac.uk/policyandsecurity/ and Jisc's privacy policy at https://www.jisc.ac.uk/website/privacy-notice

For help and support help@jisc.ac.uk

Secured by F-Secure Anti-Virus CataList Email List Search Powered by the LISTSERV Email List Manager