Anything special other than a (potentially optimized) multi-shell table
that you can put in the DiffusionVector.txt file?
Gordon
On 10/25/2010 08:27 AM, kochunov wrote:
> I'd suggest you use MGH dti sequence for this as it is superior to the
> Siemens DTI sequence.
> pk
> -----Original Message-----
> From: FSL - FMRIB's Software Library [mailto:[log in to unmask]] On Behalf
> Of David Gutman
> Sent: Monday, October 25, 2010 8:26 AM
> To: [log in to unmask]
> Subject: [FSL] Question about DSI on Siemens..
>
> This is a bit off topic.. but does anyone have any experience
> collecting DSI data on a Siements 3T Tim Trio? We are interested in
> comparing DTI and DSI data.. and our current scanner doesn't have a
> DSI protocol installed and we were debating the feasibility of
> implementing it at Emory...
>
>
>
> dg
>
|