Hi Alex,
As well as using the On and Off timings for a Square wave to input
experimental timings you have the option to change the "Basic Shape"
on the EVs tab of the GLM setup GUI to , for example, read timings
from 1 column or 3 column format ascii files. Take a look at the
bubble help for the "Basic Shape" to see more on that (just leave the
mouse pointer on the Basic Shape selection box for a few seconds).
Cheers, Mark.
----
Dr Mark Woolrich
EPSRC Advanced Research Fellow University Research Lecturer
Oxford University Centre for Functional MRI of the Brain (FMRIB),
John Radcliffe Hospital, Headington, Oxford OX3 9DU, UK.
Tel: (+44)1865-222782 Homepage: http://www.fmrib.ox.ac.uk/~woolrich
On 6 May 2009, at 18:26, SUBSCRIBE FSL Alex rigon wrote:
> Hi I need something like log files (which are used for SPM for
> example)
> for analyzing the data with FSL, or is sufficient to put the seconds
> in the ON
> and OFF slot in the full model setup?
>
> I mean the log files that could exit from, for example, the e-prime
> program
> used for presenting the stimuli.
>
|