Dear Fleur,
> I am having problems with the contrast manager in SPM. I am alternatively
> using SPM2 and 5 for fMRI studies and VBM respectively. I can no longer
> define a contrast name in the contrast manager of both versions, therefore
> preventing me from making new contrasts.
> I would be very appreciative of your suggestions,
Could it be that - for what reason whatsoever - your result directory (or the files in it) are write protected? (Perhaps through copying across machines, platforms, user-accounts, etc.). Than this behaviour would be normal.
Also mixing SPM2 and SPM5 is not generally a good idea, but that might not cause the problem here.
Good luck,
Karsten
--
-------------------------------------------------------------
Karsten Specht, PhD
Department of Biological and Medical Psychology
& National Competence Centre for functional MRI
University of Bergen
Jonas Lies vei 91
5009 Bergen
Norway
Tel.: +47-555-86279
Fax: +47-555-89872
[log in to unmask]