JiscMail Logo
Email discussion lists for the UK Education and Research communities

Help for ACB-CLIN-CHEM-GEN Archives


ACB-CLIN-CHEM-GEN Archives

ACB-CLIN-CHEM-GEN Archives


ACB-CLIN-CHEM-GEN@JISCMAIL.AC.UK


View:

Message:

[

First

|

Previous

|

Next

|

Last

]

By Topic:

[

First

|

Previous

|

Next

|

Last

]

By Author:

[

First

|

Previous

|

Next

|

Last

]

Font:

Proportional Font

LISTSERV Archives

LISTSERV Archives

ACB-CLIN-CHEM-GEN Home

ACB-CLIN-CHEM-GEN Home

ACB-CLIN-CHEM-GEN  2001

ACB-CLIN-CHEM-GEN 2001

Options

Subscribe or Unsubscribe

Subscribe or Unsubscribe

Log In

Log In

Get Password

Get Password

Subject:

DPC Immulite new PTH assay Cat No. LKPP1 or LKPP5

From:

Roger Ekins <[log in to unmask]>

Reply-To:

Roger Ekins <[log in to unmask]>

Date:

Fri, 9 Nov 2001 11:41:17 +0000

Content-Type:

text/plain

Parts/Attachments:

Parts/Attachments

text/plain (100 lines)

It's  many years since my lab offered PTH assays (using our own
reagents and assay systems, not kits) as part of its SAS menu, but in
those days we recognized that "PTH" in blood represents a can of
worms containing a miscellaneous collection of different molecules -
intact PTH, fragments, etc. The introduction of 'two site' assays
increased assay specificity, since many  fragments would not react
simultaneously with both antibodies. But this in itself does not
guarantee that the assay system responds only the intact polypeptide,
and is unaffected by fragments (some of which may interact with one
or other of the antibodies used, possibly causing assay bias).

In short even though PTH is an analyte of relatively simple molecular
structure, and a 'right answer' to a measurement of its concentation
in blood is in principle attainable , the 'right answer' will be
obtained only if the assay system responds solely to the intact
molecule. Also two PTH assay systems using different antibodies are
likely to agree only if  both respond only to the intact molecule
even though both rely on the same "pure" PTH preparation as
calibrant.  If they don't, this is good evidence that one or other,
or both, are also responding to fragments.  In other words one or
other or both assays constitute invalid 'analytical assays', and are
therefore, in effect, 'comparative assays' as defined by Finney many
years ago.

Kit manufacturers faced with this sort of problem often cover up by
altering the numbers on the standards so as to bring  reference
ranges more or less into line. (A notorious example of this was the
misrepresentation of the values of FT4  standards by certain
manufacturers)    But this is in principle dangerous because it lulls
users into a false sense of security, concealing the possibility that
the various assays may give different results with certain
pathological samples.

Johnathan Middle is therefore right in asking  "which (of two
methods) is right?" if they yield different results. But I question
his argument that the expression of  results of  measurements in SI
units implies that they " must therefore be traceable back to a
primary standard which contains a certified molar content of a single
defined chemical entity ('PTH') and this entity must be the same as
the single defined chemical entity ('PTH') in all patient samples".

We can express the results of a gravimetric measurement in Kgs  (a
well known SI unit) , but this does not imply that that the
measurement of the weight of a mixture of different substances  (and
the expression of the result in Kgs) is inadmissible.  In other
words, the expression of a result in SI units does not imply that the
measurement is of the amount or concentration of a "single  defined
chemical entity".  JM is, I think, confusing  the issue of the units
used to express assay results with that of whether an assay
constitutes  valid "analytical assay", i.e an assay that responds
only to a single molecularly homogeneous substance present in
standards and unknowns.

In practice, many - probably most - of the proteins measured by
immunoassay do not fit this description, and are of heterogeneous
molecular composition.   HCG is a typical example.  An assay of HCG
in blood is thus a "comparative assay" . It has long been known that
such assays cannot be standardised.  Nor do they have  "right
answers".  But this has nothing to do with the nature of the units in
which results are expressed

Regrettably  organisations such as NIBSC,  and others have - by
distributing international refence preparations whose analyte
"content" is expressed in international units  (claimed as
constituting  a "common currency") - been the originators and
principal perpetuators of the myth that the results of different
comparative assays (on individual samples) should be identical when
expressed in such units, and that if they are not there is something
wrong with the assays or their standardisation.

Such organisations  have stubbornly resisted the implication that the
only way of dealing with this problem (other than by developing
assays for each component of a heterogeneous analyte, using, eg,
microarray chip technology) is by  abandoning the use of either  SI
or international units to express assay results , and to replace them
by  "method dependant" units. Hopefully this would at last destroy
the fiction that the results of different (comparative) immunoassays
should be numerically the same or necessarily possess the same
diagnostic value.




--
Regards

Roger

Molecular Endocrinology
University College London Medical School
London W1N 8AA

Fax +44 20 7580 2737
Phone +44 20 7679 9410

The information in this e-mail is confidential and may be legally
privileged. It is intended for the exclusive attention of the addressee
stated above and should not be copied or disclosed to any other
without the express agreement of the sender.

Top of Message | Previous Page | Permalink

JiscMail Tools


RSS Feeds and Sharing


Advanced Options


Archives

April 2024
March 2024
February 2024
January 2024
December 2023
November 2023
October 2023
September 2023
August 2023
July 2023
June 2023
May 2023
April 2023
March 2023
February 2023
January 2023
December 2022
November 2022
October 2022
September 2022
August 2022
July 2022
June 2022
May 2022
April 2022
March 2022
February 2022
January 2022
December 2021
November 2021
October 2021
September 2021
August 2021
July 2021
June 2021
May 2021
April 2021
March 2021
February 2021
January 2021
December 2020
November 2020
October 2020
September 2020
August 2020
July 2020
June 2020
May 2020
April 2020
March 2020
February 2020
January 2020
December 2019
November 2019
October 2019
September 2019
August 2019
July 2019
June 2019
May 2019
April 2019
March 2019
February 2019
January 2019
December 2018
November 2018
October 2018
September 2018
August 2018
July 2018
June 2018
May 2018
April 2018
March 2018
February 2018
January 2018
December 2017
November 2017
October 2017
September 2017
August 2017
July 2017
June 2017
May 2017
April 2017
March 2017
February 2017
January 2017
December 2016
November 2016
October 2016
September 2016
August 2016
July 2016
June 2016
May 2016
April 2016
March 2016
February 2016
January 2016
December 2015
November 2015
October 2015
September 2015
August 2015
July 2015
June 2015
May 2015
April 2015
March 2015
February 2015
January 2015
December 2014
November 2014
October 2014
September 2014
August 2014
July 2014
June 2014
May 2014
April 2014
March 2014
February 2014
January 2014
December 2013
November 2013
October 2013
September 2013
August 2013
July 2013
June 2013
May 2013
April 2013
March 2013
February 2013
January 2013
December 2012
November 2012
October 2012
September 2012
August 2012
July 2012
June 2012
May 2012
April 2012
March 2012
February 2012
January 2012
December 2011
November 2011
October 2011
September 2011
August 2011
July 2011
June 2011
May 2011
April 2011
March 2011
February 2011
January 2011
December 2010
November 2010
October 2010
September 2010
August 2010
July 2010
June 2010
May 2010
April 2010
March 2010
February 2010
January 2010
December 2009
November 2009
October 2009
September 2009
August 2009
July 2009
June 2009
May 2009
April 2009
March 2009
February 2009
January 2009
December 2008
November 2008
October 2008
September 2008
August 2008
July 2008
June 2008
May 2008
April 2008
March 2008
February 2008
January 2008
December 2007
November 2007
October 2007
September 2007
August 2007
July 2007
June 2007
May 2007
April 2007
March 2007
February 2007
January 2007
2006
2005
2004
2003
2002
2001
2000
1999
1998


JiscMail is a Jisc service.

View our service policies at https://www.jiscmail.ac.uk/policyandsecurity/ and Jisc's privacy policy at https://www.jisc.ac.uk/website/privacy-notice

For help and support help@jisc.ac.uk

Secured by F-Secure Anti-Virus CataList Email List Search Powered by the LISTSERV Email List Manager