Hi Takanori,
Thanks for your response. Again, need to clarify. In the "corrected_micrographs.star" file #2 column (below) lists dose-weighted sums, even if I am getting the error mentioned above?
What would be the way to check whether the dose filter was applied to an output sum?
Thanks,
Elena
# RELION; version 3.0.2
data_
loop_
_rlnMicrographNameNoDW #1
_rlnMicrographName #2
_rlnMicrographMetadata #3
_rlnAccumMotionTotal #4
_rlnAccumMotionEarly #5
_rlnAccumMotionLate #6
MotionCorr/job014/tif/20190311_15271303_noDW.mrc MotionCorr/job014/tif/20190311_15271303.mrc MotionCorr/job014/tif/20
190311_15271303.star 85.791220 20.033542 65.757678
########################################################################
To unsubscribe from the CCPEM list, click the following link:
https://www.jiscmail.ac.uk/cgi-bin/webadmin?SUBED1=CCPEM&A=1
|