Dear Tali,
I don't think anyone is using the Analyze format any more. Could it be
that your data are in CIFTI format? If so, the easiest would be to
convert them in NIfTI/GIfTI format and feed these into SPM. Let me know
if this is indeed the case as it's something I worked on earlier this year.
Best regards,
Guillaume.
On 28/08/2019 13:08, Tali Weiss wrote:
> Hi all,
> We are trying to use SPM (specifically spectral DCM) on HCP data. We have been having a hard time importing the data into SPM. to be specific:
>
> 1) is it the case that SPM can only do spectral DCM on data saved in the old 'analyze' format. If that is not the case can you point us to instructions for doing that ?
>
> 2) if we have to convert to the analyze format do you know how to do that. As we understand HCP has files in nifti and also nifti formats and we tried tools like dcm2nii and dcm2niix but they did not work.
>
> thanks in advance.
>
--
Guillaume Flandin, PhD
Wellcome Centre for Human Neuroimaging
UCL Queen Square Institute of Neurology
London WC1N 3BG
|