JiscMail Logo
Email discussion lists for the UK Education and Research communities

Help for ACB-CLIN-CHEM-GEN Archives


ACB-CLIN-CHEM-GEN Archives

ACB-CLIN-CHEM-GEN Archives


ACB-CLIN-CHEM-GEN@JISCMAIL.AC.UK


View:

Message:

[

First

|

Previous

|

Next

|

Last

]

By Topic:

[

First

|

Previous

|

Next

|

Last

]

By Author:

[

First

|

Previous

|

Next

|

Last

]

Font:

Proportional Font

LISTSERV Archives

LISTSERV Archives

ACB-CLIN-CHEM-GEN Home

ACB-CLIN-CHEM-GEN Home

ACB-CLIN-CHEM-GEN  June 2016

ACB-CLIN-CHEM-GEN June 2016

Options

Subscribe or Unsubscribe

Subscribe or Unsubscribe

Log In

Log In

Get Password

Get Password

Subject:

Re: Ammonia

From:

Leila Cornes <[log in to unmask]>

Reply-To:

Leila Cornes <[log in to unmask]>

Date:

Fri, 10 Jun 2016 14:23:16 +0100

Content-Type:

text/plain

Parts/Attachments:

Parts/Attachments

text/plain (251 lines)

Sorry, only just seen this.
To avoid delay in diagnosis, which is so important as Mick and others
have quite rightly pointed out, we accept the samples and the lab
staff put the comment below on the report, in practice, most samples
still have results within the reference range even if they have not
been collected or transported under ideal conditions. This approach
answers the clinical question in many cases without rebleeding the
baby/child.

"Please note: this sample did not arrive in the laboratory on ice. The
 ammonia result may therefore be falsely high. If the result is above the
 reference range please send a repeat sample on ice urgently."

Leila Cornes
Southmead Hospital, Bristol

On 30/04/2016, Gavin Murdock <[log in to unmask]> wrote:
> Hi
>
> I agree that anytime a specimen is rejected for analysis, for not meeting
> pre-analytical requirements, there is the danger of missing or delaying the
> diagnosis of a medical emergency.
>
> In the current regulatory environment we are required to have all our
> procedures documented and to audit them to ensure that they are complied
> with.
>
> With ammonia there is much published information about the effect of
> delayed separation on the accuracy of the result but no consensus, that I
> could find, on the maximum duration acceptable between collection of the
> sample and separation of the plasma from the cells. Many commentators state
> that the sample should be placed on ice immediately and then centrifuged at
> 4 ºC but fail to state how much time can elapse between placing the sample
> on ice and centrifuging.
>
> I personally am happy to process a sample that has arrived in the lab in a
> "reasonable" time-frame and to add a free text comment to highlight the
> effect that delayed separation will have on the result. For less
> experienced members of staff you have to have an SOP which clarifies where
> the line is drawn or we risk processing samples which are several hours old
> and sending them out with an automatic comment.
>
> It would be appreciated if Dr Henderson could share the maximum time
> allowed to elapse between sample collection and separation that he has
> documented in his lab. I know from attending a BIMDG meeting that he has
> much experience in this topic.
>
> Regards,
> Gavin Murdock
>
> On 29 April 2016 at 09:13, Henderson Mick (LEEDS TEACHING HOSPITALS NHS
> TRUST) <[log in to unmask]> wrote:
>
>> Dear Colleagues,
>> can I urge extreme caution when enforcing policies that result in the
>> rejection of samples for ammonia analysis.
>> At the very least such a policy must be discussed with the clinical users
>> of the service.
>> Hyerammonaemia, at levels above 350umol/L, is likely to be a medical
>> emergency with potentially irreversible consequences for brain function
>> and
>> may be lethal.
>> There is a balance to be struck between the obligation to report accurate
>> results with the clinical imperative to identify dangerously aberrant
>> biochemistry.
>> Clinical teams are much more likely to quickly repeat a blood test when
>> presented with a high result on a 'delayed' sample.3
>> Such results must, of course be accompanied by an appropriate warning and
>> must be telephoned.
>> We are aware of clinical catastrophes caused by the rejection of samples
>> that were then not repeated for 24 hours, for a variety of reasons.
>> If a patient has an inborn error of metabolism the metabolic crisis can
>> deepen rapidly.
>>
>> Best Wishes,
>>
>> Mick Henderson
>>
>> Dr MJ Henderson
>> Laboratory Director
>> Willink Biochemical Genetics Unit                     Biochemical
>> Genetics
>> Manchester Centre for Genomic Medicine         St James’s University
>> Hospital
>> Central Manchester University Hospitals            Leeds Teaching
>> Hospitals Trust
>> Saint Mary's Hospital                                        Beckett
>> Street
>> Oxford Road, Manchester.  M13 9WL                Leeds.   LS9 7TF
>> Phone:0161 701 2137                                    Phone:0113 206
>> 4107
>> ________________________________________
>> From: Clinical biochemistry discussion list [
>> [log in to unmask]] On Behalf Of Gavin Murdock [
>> [log in to unmask]]
>> Sent: 28 April 2016 22:13
>> To: [log in to unmask]
>> Subject: Re: Ammonia
>>
>> 1. Ammonia in plasma exists in equilibrium with the ammonium anion.
>> Ammonia is also present in the atmosphere. When the sample is collected
>> there is the possibility of the equilibrium being disturbed by the
>> addition
>> or loss of ammonia to the air space.
>>
>> To mitigate against this affect we only analyse samples that arrive in
>> the
>> lab within 15 minutes of collection. You could reject grossly
>> under-filled
>> specimens but my experience is that such specimens are likely to be
>> haemolysed and so would be rejected on that basis - ammonia is present in
>> red cells at ~3 times the concentration of plasma.
>>
>> 2. The key step is to separate the plasma from the cells. Once that has
>> happened ammonia still increases due to deamination reactions but at a
>> slower rate. Low temperatures retard these reactions and so increase the
>> stability.
>>
>> We allow promptly separated plasma to be refrigerated if it can be
>> analysed within 2 hours, otherwise it should be frozen.
>>
>> Gavin
>>
>> On 28 April 2016 at 14:00, Pullan Nicola (ROYAL UNITED HOSPITALS BATH NHS
>> FOUNDATION TRUST) <[log in to unmask]<mailto:[log in to unmask]>>
>> wrote:
>> Hello,
>>
>> Can anyone help with the following?
>>
>> 1.      Our pack insert (Cobas) states that EDTA blood tubes should be
>> full for ammonia analysis. We make no provision for this currently and
>> don't bounce requests if the bottles are under-filled. Any opinion?
>>
>> 2.      If samples are separated from the cells and aliquoted into a
>> sealed false bottomed tube for analysis at a later point e.g. if analyser
>> out of action, any idea of stability?
>>
>> Many thanks for any answers in advance.
>>
>> Best wishes,
>>
>> Nicola
>> Nicola Pullan
>> Principal Clinical Biochemist
>> Royal United Hospitals Bath NHS Foundation Trust
>> Combe Park, Bath, BA1 3NG
>> Dir Line: 01225 824711
>> Visit our website at: www.ruh.nhs.uk/pathology<
>> http://www.ruh.nhs.uk/pathology>
>>
>>
>>
>>
>> ********************************************************************************************************************
>>
>> This message may contain confidential information. If you are not the
>> intended recipient please inform the
>> sender that you have received the message in error before deleting it.
>> Please do not disclose, copy or distribute information in this e-mail or
>> take any action in reliance on its contents:
>> to do so is strictly prohibited and may be unlawful.
>>
>> Thank you for your co-operation.
>>
>> NHSmail is the secure email and directory service available for all NHS
>> staff in England and Scotland
>> NHSmail is approved for exchanging patient data and other sensitive
>> information with NHSmail and GSi recipients
>> NHSmail provides an email address for your career in the NHS and can be
>> accessed anywhere
>>
>>
>> ********************************************************************************************************************
>>
>> ------ACB discussion List Information--------
>> This is an open discussion list for the academic and clinical community
>> working in clinical biochemistry.
>> Please note, archived messages are public and can be viewed via the
>> internet. Views expressed are those of the individual and they are
>> responsible for all message content.
>> ACB Web Site
>> http://www.acb.org.uk
>> Green Laboratories Work
>> http://www.laboratorymedicine.nhs.uk
>> List Archives
>> http://www.jiscmail.ac.uk/lists/ACB-CLIN-CHEM-GEN.html
>> List Instructions (How to leave etc.)
>> http://www.jiscmail.ac.uk/
>>
>> ------ACB discussion List Information-------- This is an open discussion
>> list for the academic and clinical community working in clinical
>> biochemistry. Please note, archived messages are public and can be viewed
>> via the internet. Views expressed are those of the individual and they
>> are
>> responsible for all message content. ACB Web Site http://www.acb.org.uk
>> Green Laboratories Work http://www.laboratorymedicine.nhs.uk List
>> Archives http://www.jiscmail.ac.uk/lists/ACB-CLIN-CHEM-GEN.html List
>> Instructions (How to leave etc.) http://www.jiscmail.ac.uk/
>>
>>
>> ********************************************************************************************************************
>>
>> This message may contain confidential information. If you are not the
>> intended recipient please inform the
>> sender that you have received the message in error before deleting it.
>> Please do not disclose, copy or distribute information in this e-mail or
>> take any action in reliance on its contents:
>> to do so is strictly prohibited and may be unlawful.
>>
>> Thank you for your co-operation.
>>
>> NHSmail is the secure email and directory service available for all NHS
>> staff in England and Scotland
>> NHSmail is approved for exchanging patient data and other sensitive
>> information with NHSmail and GSi recipients
>> NHSmail provides an email address for your career in the NHS and can be
>> accessed anywhere
>>
>>
>> ********************************************************************************************************************
>>
>
> ------ACB discussion List Information--------
> This is an open discussion list for the academic and clinical community
> working in clinical biochemistry.
> Please note, archived messages are public and can be viewed via the
> internet. Views expressed are those of the individual and they are
> responsible for all message content.
> ACB Web Site
> http://www.acb.org.uk
> Green Laboratories Work
> http://www.laboratorymedicine.nhs.uk
> List Archives
> http://www.jiscmail.ac.uk/lists/ACB-CLIN-CHEM-GEN.html
> List Instructions (How to leave etc.)
> http://www.jiscmail.ac.uk/
>

------ACB discussion List Information--------
This is an open discussion list for the academic and clinical community working in clinical biochemistry.
Please note, archived messages are public and can be viewed via the internet. Views expressed are those of the individual and they are responsible for all message content.
ACB Web Site
http://www.acb.org.uk
Green Laboratories Work
http://www.laboratorymedicine.nhs.uk
List Archives
http://www.jiscmail.ac.uk/lists/ACB-CLIN-CHEM-GEN.html
List Instructions (How to leave etc.)
http://www.jiscmail.ac.uk/

Top of Message | Previous Page | Permalink

JiscMail Tools


RSS Feeds and Sharing


Advanced Options


Archives

April 2024
March 2024
February 2024
January 2024
December 2023
November 2023
October 2023
September 2023
August 2023
July 2023
June 2023
May 2023
April 2023
March 2023
February 2023
January 2023
December 2022
November 2022
October 2022
September 2022
August 2022
July 2022
June 2022
May 2022
April 2022
March 2022
February 2022
January 2022
December 2021
November 2021
October 2021
September 2021
August 2021
July 2021
June 2021
May 2021
April 2021
March 2021
February 2021
January 2021
December 2020
November 2020
October 2020
September 2020
August 2020
July 2020
June 2020
May 2020
April 2020
March 2020
February 2020
January 2020
December 2019
November 2019
October 2019
September 2019
August 2019
July 2019
June 2019
May 2019
April 2019
March 2019
February 2019
January 2019
December 2018
November 2018
October 2018
September 2018
August 2018
July 2018
June 2018
May 2018
April 2018
March 2018
February 2018
January 2018
December 2017
November 2017
October 2017
September 2017
August 2017
July 2017
June 2017
May 2017
April 2017
March 2017
February 2017
January 2017
December 2016
November 2016
October 2016
September 2016
August 2016
July 2016
June 2016
May 2016
April 2016
March 2016
February 2016
January 2016
December 2015
November 2015
October 2015
September 2015
August 2015
July 2015
June 2015
May 2015
April 2015
March 2015
February 2015
January 2015
December 2014
November 2014
October 2014
September 2014
August 2014
July 2014
June 2014
May 2014
April 2014
March 2014
February 2014
January 2014
December 2013
November 2013
October 2013
September 2013
August 2013
July 2013
June 2013
May 2013
April 2013
March 2013
February 2013
January 2013
December 2012
November 2012
October 2012
September 2012
August 2012
July 2012
June 2012
May 2012
April 2012
March 2012
February 2012
January 2012
December 2011
November 2011
October 2011
September 2011
August 2011
July 2011
June 2011
May 2011
April 2011
March 2011
February 2011
January 2011
December 2010
November 2010
October 2010
September 2010
August 2010
July 2010
June 2010
May 2010
April 2010
March 2010
February 2010
January 2010
December 2009
November 2009
October 2009
September 2009
August 2009
July 2009
June 2009
May 2009
April 2009
March 2009
February 2009
January 2009
December 2008
November 2008
October 2008
September 2008
August 2008
July 2008
June 2008
May 2008
April 2008
March 2008
February 2008
January 2008
December 2007
November 2007
October 2007
September 2007
August 2007
July 2007
June 2007
May 2007
April 2007
March 2007
February 2007
January 2007
2006
2005
2004
2003
2002
2001
2000
1999
1998


JiscMail is a Jisc service.

View our service policies at https://www.jiscmail.ac.uk/policyandsecurity/ and Jisc's privacy policy at https://www.jisc.ac.uk/website/privacy-notice

For help and support help@jisc.ac.uk

Secured by F-Secure Anti-Virus CataList Email List Search Powered by the LISTSERV Email List Manager