-----BEGIN PGP SIGNED MESSAGE-----
Hash: SHA1
Dear Jacob,
maybe you should take a look at shelxl, platon and the Goodness of Fit. You
might like it.
Best,
Tim
On Friday, February 05, 2016 05:56:40 PM Keller, Jacob wrote:
> What about the following suggestion for information content quantification:
>
> The sum of (I/sigma * sqrt(Nmeas)) in resolution bins of uniform Nmeas
>
> Thus, roughly speaking, a dataset to 2 Angstrom would have twice as much
> information with multiplicity of 16 versus 4. One might be able to use the
> quantity to assess better what parameters to model.
> JPK
- --
- --
Paul Scherrer Institut
Tim Gruene
- - persoenlich -
OFLC/102
CH-5232 Villigen PSI
phone: +41 (0)56 310 5754
GPG Key ID = A46BEE1A
-----BEGIN PGP SIGNATURE-----
Version: GnuPG v2
iD8DBQFWtQ87UxlJ7aRr7hoRAirWAJ9BfwzEr1x/fHs1W+wv2s9fy3qTTQCg/yuf
BfRyfXiXw87F/D6Afl25v5U=
=ceJF
-----END PGP SIGNATURE-----
|