Mark said to use a lower resolution version of the standard space template
as the reference image if you donšt want to upsample.
Peace,
Matt.
On 8/26/15, 5:32 PM, "FSL - FMRIB's Software Library on behalf of Andrew
Mattarella-Micke" <[log in to unmask] on behalf of
[log in to unmask]> wrote:
>Hi Mark,
>
>Thanks for the quick reply. Your response seems to imply that
>permanently upsampling the functional data is a necessary part of the
>registration process. Is it possible to align the functional data to the
>standard without matching its resolution?
>
>I think my question is based on either a misunderstanding about what
>"flirt -applyxfm" does (why must it upsample, if it is applying a
>transform calculated before?), or what command would be appropriate to
>bring datasets into alignment.
>
>Thanks for your patience,
>
>Andrew
|