Hi Drew,
would it be possible that you created the VOI.mat files with different
versions of SPM? To get a better feel of what is going on, look at the
fields of the xY structure stored in VOI.mat files:
>> load VOI_1.mat
>> xY
>> load VOI_2.mat
>> xY
If there is an extra field in some of the files, (let me know what that
field is and) just remove it beforehand:
>> xY = rmfield(xY,'extra_field');
>> save VOI_x.mat xY -v6
Best regards,
Guillaume.
On 02/04/15 18:46, Sevel,Landrew S wrote:
> Hi all,
>
> I'm receiving an error in specifying individual DCMs from a generic
> model for only certain subjects using spm_dcm_voi:
>
> Subscripted assignment between dissimilar structures.
>
> Error in spm_dcm_voi (line 53)
> DCM.xY(i) = xY;
>
> Does anyone have any tips for fixing this?
>
> Thanks,
>
> Drew
--
Guillaume Flandin, PhD
Wellcome Trust Centre for Neuroimaging
University College London
12 Queen Square
London WC1N 3BG
|