In the 2D-classification it is the same model.star file, but one needs to
look at the SSNR column in the data_model_class_X tables for each class.
The resolution where the SSNR drops below 1 is the resolution of that
class.
HTH,
S
> They are presented in a table in the [CLASS3Dname]_model.star files, which
> you can inspect with a text editor. You need to manually find the
> AngstromResolution and GoldStandardFSC columns and find where they drop
> below the magic value of 0.143.
>
>
>
>
>
> ________________________________
> From: Collaborative Computational Project in Electron cryo-Microscopy
> [[log in to unmask]] on behalf of Dmitry [[log in to unmask]]
> Sent: Tuesday, April 07, 2015 11:28 AM
> To: [log in to unmask]
> Subject: [ccpem] resolution of each 2d class
>
> Dear colleagues,
>
> I need your help related to the relion-2d classification procedure.
> Does anybody know where we can see the resolution of each result
> projection 2d class?
>
> Sincerely,
> Dmitry
>
--
Sjors Scheres
MRC Laboratory of Molecular Biology
Francis Crick Avenue, Cambridge Biomedical Campus
Cambridge CB2 0QH, U.K.
tel: +44 (0)1223 267061
http://www2.mrc-lmb.cam.ac.uk/groups/scheres
|