Hello Analysis Developers,
I am using Analysis Version 2.4 release 0 on Linux SuSe11.4.
I have assigned the H-beta methylene protons non-stereopspecifically as Hba and Hbb. Now I have the information to assign them stereospecifically ( using 3D-HNHB and HN(CO)HB). What is the best way to change the non-stereospecific assignments to stereopsecific assignmets?
I tried to set the status of prochiral protons using "Format Converter -> Process -> Check Stereo Status Prochiral". The following error came up (traceback is attached at the end of the e-mail).
I am also not able to access the help page for this pop-up window by clicking the question mark on the right bottom of the pop-up window. The designated html file is not there at the appropriate location. The missing html help file is supposed to be at the location "/home/nmrware/ccpnmr/ccpnmr2.4/python/ccpnmr/format/doc/ProchiralStatus.html"
Many thanks in advance.
with regards,
Aswani Kumar
PS: I have recently upgraded Analysis from Version 2.1 to 2.4. The way I did this was: (1) I downloaded tar file for the precompiled binaries of latest version. (2). Renamed the old ccpnmr folder to ccpnmr_2.1 (3). untarred the new file
traceback
=============================================================================================================================
Exception in Tkinter callback
Traceback (most recent call last):
File "/home/nmrware/ccpnmr/python2.6/lib/python2.6/lib-tk/Tkinter.py", line 1410, in __call__
return self.func(*args)
File "/home/nmrware/ccpnmr/ccpnmr2.4/python/ccpnmr/format/gui/ProchiralStatusPopup.py", line 424, in setStereo
(stereoStatus,stereoStatusChanged,resChanged,resonances) = self.chainResonancesDict[self.resParent][chain][i]
=============================================================================================================================
|