Hello,
Thanks for the email. Believe it or not that bug cropped up a few months ago and I fixed it, but evidently only not for Windows, which causes special problems because of the drive ('E:'). I've fixed that now, patch on the update server.
Wayne
On 2 Jul 2014, at 09:39, Fabian Hiller wrote:
> Hi,
>
> I encountered an issue when trying to open UCSF spectra in the latest Analysis version (2.4.0) with all updates installed on Windows 7 64bit. No contours were shown at all, and after digging a bit I found that the path to the UCSF file in data locations got somehow mangled. Instead of "E:/abc/myspectrum.ucsf" the data location was "E:/bc/myspectrum.ucsf", the first character of the directory name is missing.
>
> I did try a few variations, and the actual directory name doesn't seem to play any role. What seems to be important is that my directory hierarchy is only one level deep. If I change the paths to "E:/abc/def/myspectrum.ucsf" no mangling occurs.
>
> Regards
> Fabian
|