Dear Almudena,
i think your problems com from the Flag in your input.mtz . You have to check if your mtz has the correct column name. And you have to designate the one which correspond to PHIB.
It depend from which programm com your input.mtz .
Hope to help.
Nicolas
________________________________________
De : CCP4 bulletin board [[log in to unmask]] de la part de Almudena Ponce Salvatierra [[log in to unmask]]
Envoyé : jeudi 5 juin 2014 11:43
Ŕ : [log in to unmask]
Objet : [ccp4bb] solvent flattening with resolve - phenix
Dear all,
I am trying to get a sharper map with RESOLVE in Phenix and I provide the .mtz or high resolution data as well as the mtz corresponding to experimental data. However I get the following message, and I don't really know how to fix it even though it looks quite silly. Might be that today I am not inspired, :-P
Please identify the column 'PHIB' in your input data file.
You can specify all columns to use in 'input_labels' like this:
FP SIGFP PHIB FOM HLA HLB HLC HLD
where you have to put something in each of these 8 spots
(use None for missing ones). You currently have:
FP SIGFP None FOM hltofom.ABCD.A hltofom.ABCD.B hltofom.ABCD.C hltofom.ABCD.D
Possibilities are...
FreeRflag FP SIGFP FC PHIC FC_ALL PHIC_ALL FWT PHWT DELFWT PHDELWT FOM FC_ALL_LS PHIC_ALL_LS hltofom.ABCD.A hltofom.ABCD.B hltofom.ABCD.C hltofom.ABCD.D None
Any suggestions?
Thank you very much in advance.
Best wishes, from sunny Göttingen!
Almudena
--
Almudena Ponce-Salvatierra
Macromolecular crystallography and Nucleic acid chemistry
Max Planck Institute for Biophysical Chemistry
Am Fassberg 11 37077 Göttingen
Germany
|