Colleagues,
Sorry to bother for something really minor. The Refmac usually always recognizes tetrahedral SO4 groups and there were no problems related to its geometry. Two attached files demonstrate SO4 geometry before and after refinement. Would you be able to point me to mistake I’m doing?
Thank you.
Regards,
Vaheh Oganesyan, PhD
Antibody discovery and protein engineering
MedImmune, LLC.
www.medimmune.com
To the extent this electronic communication or any of its attachments contain information that is not in the public domain, such information is considered by MedImmune to be confidential and proprietary. This communication is expected to be read and/or used only by the individual(s) for whom it is intended. If you have received this electronic communication in error, please reply to the sender advising of the error in transmission and delete the original message and any accompanying documents from your system immediately, without copying, reviewing or otherwise using them for any purpose. Thank you for your cooperation.
To the extent this electronic communication or any of its attachments contain information that is not in the public domain, such information is considered by MedImmune to be confidential and proprietary. This communication is expected to be read and/or used only by the individual(s) for whom it is intended. If you have received this electronic communication in error, please reply to the sender advising of the error in transmission and delete the original message and any accompanying documents from your system immediately, without copying, reviewing or otherwise using them for any purpose. Thank you for your cooperation.
|