Subject:

Re: Clinitek Status+

From:

"HOLLOWOOD NICKY (RCD) PATHOLOGY" <[log in to unmask]>

Reply-To:

ACB Point-of-Care Testing <[log in to unmask]>

Date:

Thu, 12 Dec 2013 11:40:30 -0000

Content-Type:

text/plain

Parts/Attachments:

Parts/Attachments

text/plain (204 lines)

HI Peter,

Before we changed to the urilyzer 100 Pro (sterilab) we had the clinitek
status devices in place.  We had the option of scanning the barcode with
the lot number information in activated, however entry of the expiry
date is manual therefore can be "fiddled" by the user.  One of the
reasons for having this turned on was that our CPA inspectors identified
this as a requirement for meeting the POCT CPA standards.

In terms of quality control our users do this weekly, we use
quantimetrix dropper solution which is stable at room temp for one month
after opening.  We keep stocks in the lab and distribute once a month.
We have a lockout imposed on our system so doing it is compulsory.  We
believe weekly QC is important as it tests the integrity of the strips,
as they are not individually wrapped like many other POCT consumables it
is very easy for these to go off quickly if the top isn't replaced etc.
We have had a couple of incidents where we have picked this up as a
direct result of the quality control failing.

Thanks

Nicky Hollowood
 
POCT Manager
Harrogate & District NHS Foundation Trust
01423 555858   
[log in to unmask] 
 
Please note I work Wednesday to Friday. 
Margaret Wildridge is in post Monday-Tuesday
 
  
 
 
-----Original Message-----
From: ACB Point-of-Care Testing [mailto:[log in to unmask]] On
Behalf Of Cambridge Anthony (PLYMOUTH HOSPITALS NHS TRUST - RK9)
Sent: 12 December 2013 11:29
To: [log in to unmask]
Subject: Re: Clinitek Status+

---
This message was sent from an email address external to NHSmail but
gives the appearance of being from an NHSmail (@nhs.net) address. The
recipient should verify the sender and content before acting upon
information contained within. 

The identified sender is [log in to unmask]
---
Hi All

We send out a monthly in-house quality assurance sample which we spike.
We do not run IQC on our readers other than the ones based in the
laboratory which are used to test the in-house sample before
distribution. The product is an Alere dropper bottle. These lab readers
are also enrolled in a traditional EQA scheme to ensure quality of our
in-house sample.

We do not record lot numbers on any readers in the trust.

Regards


Tony Cambridge MSc. BSc.
Chief Biomedical Scientist
Point of Care Testing & EQA
Derriford Combined Laboratory
Level 7
Ext 52299
Direct Line: 01752 792299
New email: [log in to unmask]



50cb3d4414ecbf212e0007a9.50

Pathology POCT Page





-----Original Message-----
From: ACB Point-of-Care Testing [mailto:[log in to unmask]] On
Behalf Of Lee Peters (ABM ULHB - Laboratory Medicine - Point of Care)
Sent: 12 December 2013 11:24
To: [log in to unmask]
Subject: Re: Clinitek Status+

Hi Claire,
What QC do you use? This must be very expensive.

-----Original Message-----
From: ACB Point-of-Care Testing [mailto:[log in to unmask]] On
Behalf Of Claire Haynes
Sent: 12 December 2013 09:57
To: [log in to unmask]
Subject: Re: Clinitek Status+

Peter,

We do not have that option switched on.  I try to send out qc weekly.

Claire Haynes
Laboratory POCT Officer
Clinical Biochemistry
GSTS Pathology
Bedford Hospital

Tel: 01234 355122 4654
________________________________________
From: ACB Point-of-Care Testing [[log in to unmask]] On Behalf Of
peter taylor [[log in to unmask]]
Sent: 11 December 2013 15:54
To: [log in to unmask]
Subject: Clinitek Status+

---
This message was sent from an email address external to NHSmail but
gives the appearance of being from an NHSmail (@nhs.net) address. The
recipient should verify the sender and content before acting upon
information contained within.

The identified sender is [log in to unmask]
---
This may be the stupid question of the day. Does anyone  using the
Clinitek device ,have the option switced on of entering strip lot
number/expiry dates before each test. And how often do you run QC.

Peter

POCT Coordinator
NHS HIGHLAND
ARGYLL&BUTE
[log in to unmask]



************************************************************************
*********************
www.bedfordhospital.nhs.uk

************************************************************************
*********************
This email is confidential and privileged. If you are not the intended
recipient please accept our apologies. Please do not disclose, copy or
distribute information in this email or take any action in reliance on
its contents; to do so is strictly prohibited and may be unlawful.
Please inform us that this email has gone astray before deleting it.
Thank you for your co-operation.

************************************************************************
*********************
Cymraeg:-
Mae'r neges hon yn gyfrinachol. Os nad chi yw'r derbynnydd y bwriedid y
neges ar ei gyfer, byddwch mor garedig a rhoi gwybod i'r anfonydd yn
ddioed. Dylid ystyried un rhywd datganiadau neu sylwadau a wneir uchod
yn rhai personol, ac nid o angen rhaid yn rhai o eiddo Bwrdd Iechyd
Prifysgol GIG Abertawe Bro Morgannwg, nac unrhyw ran gyfansoddol ohoni
na chorff cysylltiedig.

Cofiwch fod yn ymwybodol ei bod yn bosibl y bydd disgwyl i Bwrdd Iechyd
Prifysgol GIG Abertawe Bro Morgannwg roi cyhoeddusrwydd i gynnwys unrhyw
ebost neu o hebiaeth a dderbynnir, yn unol ag amodau'r Ddeddf Rhyddid
Gwybodaeth 2000. I gael mwy o wybodaeth am Ryddid Gwybodaeth, cofiwch
gyfeirio at wefan Bwrdd Iechyd Prifysgol GIG Abertawe Bro Morgannwg ar
www.abm.university-trust.wales.nhs.uk

English:-
This message is confidential. If you are not the intended recipient of
the message then please notify the sender immediately.
Any of the statements or comments made above should be regarded as
personal and not necessarily those of Abertawe Bro Morgannwg University
Health Board any constituent part or connected body.

Please be aware that, under the terms of the Freedom of Information Act
2000, Abertawe Bro Morgannwg University Health Board may be required to
make public the content of any emails or correspondence received. For
further information on Freedom of Information, please refer to the
Abertawe Bro Morgannwg University Health Board  website at
www.abm.university-trust.wales.nhs.uk.

************************************************************************
********************************************

This message may contain confidential information. If you are not the
intended recipient please inform the
sender that you have received the message in error before deleting it.
Please do not disclose, copy or distribute information in this e-mail or
take any action in reliance on its contents:
to do so is strictly prohibited and may be unlawful.

Thank you for your co-operation.

NHSmail is the secure email and directory service available for all NHS
staff in England and Scotland
NHSmail is approved for exchanging patient data and other sensitive
information with NHSmail and GSi recipients
NHSmail provides an email address for your career in the NHS and can be
accessed anywhere

************************************************************************
********************************************

Top of Message | Previous Page | Permalink

JiscMail Tools


RSS Feeds and Sharing


Advanced Options


Archives

April 2024
March 2024
February 2024
January 2024
December 2023
November 2023
October 2023
September 2023
August 2023
July 2023
June 2023
May 2023
April 2023
March 2023
February 2023
January 2023
December 2022
November 2022
October 2022
September 2022
August 2022
July 2022
June 2022
May 2022
April 2022
March 2022
February 2022
January 2022
December 2021
November 2021
October 2021
September 2021
August 2021
July 2021
June 2021
May 2021
April 2021
March 2021
February 2021
January 2021
December 2020
November 2020
October 2020
September 2020
August 2020
July 2020
June 2020
May 2020
April 2020
March 2020
February 2020
January 2020
December 2019
November 2019
October 2019
September 2019
August 2019
July 2019
June 2019
May 2019
April 2019
March 2019
February 2019
January 2019
December 2018
November 2018
October 2018
September 2018
August 2018
July 2018
June 2018
May 2018
April 2018
March 2018
February 2018
January 2018
December 2017
November 2017
October 2017
September 2017
August 2017
July 2017
June 2017
May 2017
April 2017
March 2017
February 2017
January 2017
December 2016
November 2016
October 2016
September 2016
August 2016
July 2016
June 2016
May 2016
April 2016
March 2016
February 2016
January 2016
December 2015
November 2015
October 2015
September 2015
August 2015
July 2015
June 2015
May 2015
April 2015
March 2015
February 2015
January 2015
December 2014
November 2014
October 2014
September 2014
August 2014
July 2014
June 2014
May 2014
April 2014
March 2014
February 2014
January 2014
December 2013
November 2013
October 2013
September 2013
August 2013
July 2013
June 2013
May 2013
April 2013
March 2013
February 2013
January 2013
December 2012
November 2012


JiscMail is a Jisc service.

View our service policies at https://www.jiscmail.ac.uk/policyandsecurity/ and Jisc's privacy policy at https://www.jisc.ac.uk/website/privacy-notice

For help and support help@jisc.ac.uk

Secured by F-Secure Anti-Virus CataList Email List Search Powered by the LISTSERV Email List Manager