> On Behalf Of Fokke Dijkstra said:
> How can this ever work for the end user? I've just got a question from
> someone who is trying to request a queue for his job with enough
> wallclock time available. He ran into the issue that RUG-CIT and
> SARA-MATRIX publish wallclock time in hours, where NIKHEF-ELPROD
> publishes wallclock time in minutes. I'm quite sure that in the recent
> past we published minutes as well at RUG-CIT. Adding seconds into the
> mix makes the problem even worse.
The change is only for GLUE 2, GLUE 1 stays in minutes. The latest WMS does support matching against GLUE 2 attributes but I don't think anyone is using it yet, so hopefully people will have upgraded their CREAMs by the time it becomes relevant. Anyway publishing hours is definitely wrong - do they have some kind of customised info provider?
Stephen
--