On 01/15/2013 11:09 AM, Stephen Burke wrote:
> Testbed Support for GridPP member institutes [mailto:TB-
>> [log in to unmask]] On Behalf Of Stephen Jones said:
>> Yes - let me know the easy way to kick a CE out of the BDII.
> As Daniela said you can take it out of the site BDII configuration, or simply stop the bdii service on the CE itself.
>
>> On a related note, I want the CE to be "working" so that _I_ can submit jobs
>> to it through the WMS and see work flow through the system end to end.
>> Concurrently, I want the CE to be in downtime so others don't do that. Those
>> are the requirements. What's the best approach?
> If you use the -r option on job submission the WMS sends the job directly to the CE and doesn't use the BDII information.
>
> Stephen
>
Cheers, Stephen.
--
Steve Jones [log in to unmask]
System Administrator office: 220
High Energy Physics Division tel (int): 42334
Oliver Lodge Laboratory tel (ext): +44 (0)151 794 2334
University of Liverpool http://www.liv.ac.uk/physics/hep/
|