Good morning FSL team,
We have been comparing brain stem volumes in two patient groups and have used FIRST with the BrStem_bin.bmv command. This provides good volume data for both the brainstem + 4th ventricle.
My question is whether there is a way of obtaining the brainstem volume without the 4th ventricle included?
Many thanks