Hi Davide,
Problem solved.
Thanks a lot
Regards
Simon
Davide Gaudesi wrote:
> Hi Simon,
>
> the easiest way to have an "alternative" assignment is to create a new
> shift list:
> Analysis2.1.5-->Experiment --> Experiments --> Experiments tab (6th
> column from left)-->
> double click on ShiftList# activating the drop-down menu, select New
>
> Regards
>
> Davide Gaudesi, Ph.D.
>
> [log in to unmask]
>
> Dulbecco Telethon Institute c/o S. Raffaele Scientific Institute
> Center of Genomics, BioInformatics an BioStatistics
> Biomolecular NMR Laboratory Dibit2 Basilica 3A2
> Via Olgettina 58
> 20132 Milano
> Italy
>
> Tel: 00390226433497
>
>
> On 02/29/2012 10:55 AM, S.P. Skinner wrote:
>> Dear all,
>>
>> I am currently attempting to transfer assignments from a diamagnetic
>> control to a paramagnetically shifted spectrum. However, I cannot
>> propagate the assignments as some peaks are shifted upto 1ppm in both
>> dimensions and I cannot re-assign or I lose my diamagnetic assignment.
>> Is there a way to have two assignments for one protein in the same
>> project, or do I need to create a separate molecule for example to
>> represent two different "forms" of the protein?
>>
>> Kind Regards
>>
>> Simon Skinner
>>
--