JiscMail Logo
Email discussion lists for the UK Education and Research communities

Help for FSL Archives


FSL Archives

FSL Archives


FSL@JISCMAIL.AC.UK


View:

Message:

[

First

|

Previous

|

Next

|

Last

]

By Topic:

[

First

|

Previous

|

Next

|

Last

]

By Author:

[

First

|

Previous

|

Next

|

Last

]

Font:

Proportional Font

LISTSERV Archives

LISTSERV Archives

FSL Home

FSL Home

FSL  July 2011

FSL July 2011

Options

Subscribe or Unsubscribe

Subscribe or Unsubscribe

Log In

Log In

Get Password

Get Password

Subject:

AW: [FSL] Scanner aquisition parameter queries - parallel imaging and field maps

From:

Andreas Bartsch <[log in to unmask]>

Reply-To:

FSL - FMRIB's Software Library <[log in to unmask]>

Date:

Wed, 27 Jul 2011 08:33:11 +0200

Content-Type:

text/plain

Parts/Attachments:

Parts/Attachments

text/plain (86 lines)

Hi Reem,

I have no skyra experiences but:
- registration of T1-w MPRAGEs into standard space does usually not suffer from iPAT
- FIRST, VBM & FreeSurfer may be better off without acceleration. a crucial parameter is the TE as it determines how bright the dura comes out.
- if you use iPAT for the strucs, try to use more reference lines (i.e. >48, e.g. 72)

EPI:
yes, you loose signal but you reduce the effective echo spacing, i.e. the distortions, by the iPAT factor and you may be able to increase the resolution of your scans to something like 1.5mm isotropic AND keep your TE around 30ms.
but again, you loose signal and may need a 32 channel head coil, for example (not sure if the skyra supports it)

field maps:
the crucial parameter is the TE difference. every system is different, and usually you don't even operate at exactly 3T (but 2.96, for example). the 'best' TE difference depends on the fat-water shift and you may want to adjust this to your precise system (note that the skyra is more prone to inhomogeneities than the trio, for example). however, having said this you may well stick to the siemens default as it won't make >much< of a difference for the unwarping.

if you go for iPAT, use GRAPPA and not mSENSE on the siemens (bold statement but a rough guideline).

hth,
andreas


________________________________________
Von: FSL - FMRIB's Software Library [[log in to unmask]] im Auftrag von Reem Jan [[log in to unmask]]
Gesendet: Mittwoch, 27. Juli 2011 03:49
An: [log in to unmask]
Betreff: [FSL] Scanner aquisition parameter queries - parallel imaging and field maps

Dear FSLers

I’m in the process of setting up a new trial and trying to decide on acquisition parameters, particularly regarding parallel imaging (iPAT) and field maps.

We will be using a Siemens Skyra 3T MRI system, and acquiring EPIs for task fMRI and DTI as well as T1-weighted MPRAGE sequences. For iPAT we have the options of using GRAPPA or mSENSE. The default is GRAPPA.
MPRAGE

I researched the pros and cons of turning iPAT on and it seems that it would reduce acquisition time for the MPRAGE (in the case of our scanner down from 8:57 mins to 4:52 mins), however when iPAT is turned on (acceleration factor: 2), the SNR also drops from 1.41 to 1.

I plan to use the MPRAGE structural scans for VBM and FIRST analyses:

·         Would it be okay for parallel imaging to be turned on?

·         What voxel size would you recommend? In the past I have used 1x1x1mm. Is there a benefit to using smaller voxels (e.g. 0.9x0.9x0.8mm)?

EPI

I realise that the acquisition time of EPIs is unaffected by iPAT, however, it is meant to improve geometric distortion around air pockets etc, but the radiographer also told me that I can lose up to 30% of the signal.


·         I’m having trouble deciding whether to leave iPAT turned off for the DTI and fMRI sequences in order to maximise SNR, but have the risk of increased distortion. I was hoping to draw on your expertise on whether this trade-off is worthwhile?


Field maps

For the new trial I want to ensure that I acquire field maps for the fMRI dataset as per Mark Jenkinson’s advice at the FSL course and on the FSL mailing list.

·         Are there any specific considerations or would the built-in scanner parameters be okay?

Examples


·         Lastly, I have some MPRAGE and EPI images from a pilot, that have been acquired with iPAT turned on, and wondered (if it’s not too much trouble) whether I can upload examples of these so the FSL experts could tell me if their quality is good enough for me to proceed without changes.


Many thanks in advance, your advice is much appreciated.

Best regards
Reem


Reem Jan
BPharm (Hons), RegPharmNZ

PhD Student / Pharmacist
School of Pharmacy, Faculty of Medical & Health Sciences,
The University of Auckland, Private Bag 92019,
Auckland, New Zealand.
Ph: +64 9 373 7599 ext 88468. DDI: +64 9 923 8468
F: +64 9 367 7192




__________ Information from ESET NOD32 Antivirus, version of virus signature database 6327 (20110726) __________

The message was checked by ESET NOD32 Antivirus.

http://www.eset.com

Top of Message | Previous Page | Permalink

JiscMail Tools


RSS Feeds and Sharing


Advanced Options


Archives

April 2024
March 2024
February 2024
January 2024
December 2023
November 2023
October 2023
September 2023
August 2023
July 2023
June 2023
May 2023
April 2023
March 2023
February 2023
January 2023
December 2022
November 2022
October 2022
September 2022
August 2022
July 2022
June 2022
May 2022
April 2022
March 2022
February 2022
January 2022
December 2021
November 2021
October 2021
September 2021
August 2021
July 2021
June 2021
May 2021
April 2021
March 2021
February 2021
January 2021
December 2020
November 2020
October 2020
September 2020
August 2020
July 2020
June 2020
May 2020
April 2020
March 2020
February 2020
January 2020
December 2019
November 2019
October 2019
September 2019
August 2019
July 2019
June 2019
May 2019
April 2019
March 2019
February 2019
January 2019
December 2018
November 2018
October 2018
September 2018
August 2018
July 2018
June 2018
May 2018
April 2018
March 2018
February 2018
January 2018
December 2017
November 2017
October 2017
September 2017
August 2017
July 2017
June 2017
May 2017
April 2017
March 2017
February 2017
January 2017
December 2016
November 2016
October 2016
September 2016
August 2016
July 2016
June 2016
May 2016
April 2016
March 2016
February 2016
January 2016
December 2015
November 2015
October 2015
September 2015
August 2015
July 2015
June 2015
May 2015
April 2015
March 2015
February 2015
January 2015
December 2014
November 2014
October 2014
September 2014
August 2014
July 2014
June 2014
May 2014
April 2014
March 2014
February 2014
January 2014
December 2013
November 2013
October 2013
September 2013
August 2013
July 2013
June 2013
May 2013
April 2013
March 2013
February 2013
January 2013
December 2012
November 2012
October 2012
September 2012
August 2012
July 2012
June 2012
May 2012
April 2012
March 2012
February 2012
January 2012
December 2011
November 2011
October 2011
September 2011
August 2011
July 2011
June 2011
May 2011
April 2011
March 2011
February 2011
January 2011
December 2010
November 2010
October 2010
September 2010
August 2010
July 2010
June 2010
May 2010
April 2010
March 2010
February 2010
January 2010
December 2009
November 2009
October 2009
September 2009
August 2009
July 2009
June 2009
May 2009
April 2009
March 2009
February 2009
January 2009
December 2008
November 2008
October 2008
September 2008
August 2008
July 2008
June 2008
May 2008
April 2008
March 2008
February 2008
January 2008
December 2007
November 2007
October 2007
September 2007
August 2007
July 2007
June 2007
May 2007
April 2007
March 2007
February 2007
January 2007
2006
2005
2004
2003
2002
2001


JiscMail is a Jisc service.

View our service policies at https://www.jiscmail.ac.uk/policyandsecurity/ and Jisc's privacy policy at https://www.jisc.ac.uk/website/privacy-notice

For help and support help@jisc.ac.uk

Secured by F-Secure Anti-Virus CataList Email List Search Powered by the LISTSERV Email List Manager