Hello,
I wonder if these days somebody successfully works with the interface of CCPN 2.2.1 and ARIA 2.3. I have created the ARIA project from within CCPN with a shift list and a Noesy peak list. When I opened the ARIA project with ARIA GUI, it shows correct shift and peak lists in the window. However when I click the button "Select..." for the spectrum, the error popups: No CCPN peak or shift list present for molecular system... If I click the button for the shift list selection, the popup comes out and I am able to select the shift list.
If I start ARIA calculation anyway, I get this error:
Traceback (most recent call last):
File "/usr/local/aria2.3/aria2.py", line 903, in ?
verbose_level, use_condor=condor)
File "/usr/local/aria2.3/aria2.py", line 811, in run_aria
project.load_and_preprocess_data()
File "/usr/local/aria2.3/src/py/aria/Project.py", line 1426, in load_and_preprocess_data
self.read_data()
File "/usr/local/aria2.3/src/py/aria/Project.py", line 1186, in read_data
self.read_ccpn_data()
File "/usr/local/aria2.3/src/py/aria/Project.py", line 766, in read_ccpn_data
aria_spectrum = ccpnImport.makeAriaSpectrum(peakList, self.molecule)
File "/usr/local/aria2.3/src/py/aria/importFromCcpn.py", line 936, in makeAriaSpectrum
raise Exception('%s is not a NOESY.' % experiment.name)
Exception: 800Nnoesy20110101 is not a NOESY.
It seems I have this problem for all my CCPN projects, even for those which did not cause the problem early.
I appreciate any help.