Hello,
We just tried it here (on 2.1.5 and 2.2.1) and it looks like if the peak
is assigned then "Make Assigned Restraints" ignores it (so, if it is
diagonal, so the two resonances are the same) and if it is not assigned
then "Make Shift Match Restraints" has an option to "Ignore diagonal
peaks" where the tolerances are as specified in the Min/default PPM
tolerance. Which of these two buttons were you using?
Wayne
On Wed, 6 Jul 2011, Fowler, Andrew wrote:
> It's possible I'm missing something here, but is there any way under make distance
> restraints to exclude diagonal/auto peaks? If not, can this be a feature request
> for v.3 (and I'll deal with them manually for now)? I can't imagine it would be
> very hard to exclude a peak if it satisfies the condition shift 1 = shift 2 (±
> tolerance), although the special case of 4D 13C-13C NOESY would require comparing a
> second pair of shifts.
>
> Andrew
>
> --
> Dr. Andrew Fowler | University of Iowa
> Associate Director | B291 Carver Biomedical Research Building
> Medical NMR Facility | Iowa City, IA 52242
> 319-384-2937 (office) | 319-335-7273 (fax)
> [log in to unmask]
>
>
> __________________________________________________________________________________________
> Notice: This UI Health Care e-mail (including attachments) is covered by the
> Electronic Communications Privacy Act, 18 U.S.C. 2510-2521, is confidential and may
> be legally privileged. If you are not the intended recipient, you are hereby
> notified that any retention, dissemination, distribution, or copying of this
> communication is strictly prohibited. Please reply to the sender that you have
> received the message in error, then delete it. Thank you.
>
> __________________________________________________________________________________________
>
>
|