Darren,
I have working version of version 2.6.0 here, your command runs fine.
Error statement seems to say there is a missing data file. Unlikely,
but check for files intranuke_xsections-XX.dat in $GENIE/data/hadron_xsec.
You should have 4 files XX = NN, NA, piA, and piN.
You say this shows up at end of long printout. Please send that printout.
At the moment, not clear what your problem is. Have you run other GENIE
applications?
Do you have access to working version, e.g. at TRIUMF or Regina? You
can compare
your setup with theirs.
regards,
Steve Dytman
Darren Grant wrote:
> Hi
>
> Please note I am a very new user of GENIE, but have been unable to find a solution to this on the archive searches.
>
> I have completed the compile of production release 2.6.0 without any errors on the system here. In execution of the test command from the manual
>
> ./bin/ghAevgen -n 10000 -p 211 -t 1000080160 -k 0.2
>
> I am seeing the following error at the end of all the output
>
> ghAevgen: INukeHadroData.cxx:173: void genie::INukeHadroData::LoadCrossSections(): Assertion `! gSystem->AccessPathName(datafile_NN. c_str())' failed.
> Aborted
>
> I am unsure how to proceed with this error. I note that I have compiled with pyhia6 and root 5.24b on a x86_64 box running Linux 2.6.18-194.11.4.el5 with gcc (GCC) 4.1.2 20080704 (Red Hat 4.1.2-48) and GNU Fortran (GCC) 4.1.2 20080704 (Red Hat 4.1.2-48).
>
> Please let me know what information etc you might require to help debug.
>
> Best wishes
> Darren
>
|