JiscMail Logo
Email discussion lists for the UK Education and Research communities

Help for CCP4BB Archives


CCP4BB Archives

CCP4BB Archives


CCP4BB@JISCMAIL.AC.UK


View:

Message:

[

First

|

Previous

|

Next

|

Last

]

By Topic:

[

First

|

Previous

|

Next

|

Last

]

By Author:

[

First

|

Previous

|

Next

|

Last

]

Font:

Proportional Font

LISTSERV Archives

LISTSERV Archives

CCP4BB Home

CCP4BB Home

CCP4BB  September 2009

CCP4BB September 2009

Options

Subscribe or Unsubscribe

Subscribe or Unsubscribe

Log In

Log In

Get Password

Get Password

Subject:

Re: Observation:parameter ratio

From:

Ed Pozharski <[log in to unmask]>

Reply-To:

Ed Pozharski <[log in to unmask]>

Date:

Wed, 23 Sep 2009 12:55:28 -0400

Content-Type:

text/plain

Parts/Attachments:

Parts/Attachments

text/plain (84 lines)

I've seen this estimate of the determinancy point for torsion angle
refinement presented by Axel Brunger at ACA meeting this summer.  I
don't remember all the details, but no, it did not refer to the approach
described in the paper where higher resolution model is used as a
restraint.  It was simply done by equalizing the number of torsions in
the protein of certain molecular weight and number of reflections
obtained at certain resolution assuming certain solvent content.  His
point (assuming that I understood it correctly) was that when you are
working with 5A data your are definitely at the limit where even
torsional refinement may become underdetermined.  Thus you need more
restraints, and it seems that you may be able to get them from higher
resolution structures of, say, subunits of the same protein.

You make an excellent point about the histogram - just because it's in
PDB doesn't mean it's right.  I've seen 2A structures there with waters
that had hydrogens, but I won't condone that :)

On Wed, 2009-09-23 at 10:31 -0500, Pete Meyer wrote:
> > Brunger, A., DeLaBarre, B., Davies, J. & Weis, W. X-ray structure
> > determination at low resolution. ACTA CRYSTALLOGRAPHICA SECTION
> > D-BIOLOGICAL CRYSTALLOGRAPHY 65, 128-133 (2009).  
> > 
> > The paper quotes Wayne Hendrickson (says "submitted") regarding
> > "determinancy" point (i.e. where the number of observations becomes
> > equal to the number of flexible torsions (of course, in this extreme
> > case gemoetric restraints essentially become constraints and you don't
> > refine B-factrors at all.  With 50% solvent this is ~5.4A, and you are
> > far from that limit.
> 
>  From a quick glance at that paper (although not the "submitted" one), 
> it looks like this determinancy point may only apply to cases where 
> components from high resolution structures are being used at lower 
> resolution (independent components of a complex at high res vs the full 
> complex at low res).  This may or may not apply to cases where an 
> initial model refined at higher resolution is not available, although 
> I'm leaning more towards the "not applicable" side at the moment (my 
> understanding was that some level of over-determination was required. 
> Exactly what minimum level of over-determination is required is 
> something I haven't been able to find out yet).
> 
> > It is rather surprising that any reviewer anywhere would have doubts
> > about possibility to refine structural model at 3.4A.  While I don't
> > know what the referee said *exactly*, but he/she may be unaware of this
> > 
> > http://www.rcsb.org/pdb/statistics/histogram.do?mdcat=refine&mditem=ls_d_res_high&minLabel=0&maxLabel=5&numOfbars=10&name=Resolution
> 
> At 3.4 Angstroms, refinement should definitely be possible.  But I might 
> not point a reviewer at that histogram.  Assuming "mdcat=refine" is 
> limiting results to entries that have been refined, that table has 
> entries in the 20 to 70 Angstrom range, where I'd have doubts about the 
> validity of any refinement done.  So I'm not sure that the PDB is 
> filtering for cases of acceptable refinement vs any refinement at all 
> (I've seen REMARK lines in deposited entries where the authors reported 
> that the refinement statistics were not necessarily valid given the 
> resolution of the structure; it may be easier to do a few cycles of 
> refinement to satisfy deposition requirements than deposit an unrefined 
> structure at low resolution).
> 
> > 
> > 
> > 
> > On Wed, 2009-09-23 at 12:48 +0000, hugh morgan wrote:
> >> Hi, 
> >>     We are attempting to address a referees comment concerning our
> >> data/parameter ratio for a 3.4 A structure. Although the ratio is only
> >> 0.5, the R/Rfree is 25/29, which seems acceptable. Ideally I would
> >> like to include a reference showing a graph or table of data:parameter
> >> vs resolution but I have been unable to find such a paper. Please
> >> could someone point me in the right direction. 
> >> Thanks in advance
> >>
> >> Hugh
> >>
> >> P.S. It would be nice to know if this table has been published
> >> http://www-structmed.cimr.cam.ac.uk/Course/Basic_refinement/Refinement.html
> >>
> >> or something similar to this, which includes higher resolution
> >> structures
> >> http://dirac.cnrs-orleans.fr/plone/Members/hinsen/data-parameter-ratio-in-x-ray-structure-determination
> >>
> >>
> >>
-- 

Top of Message | Previous Page | Permalink

JiscMail Tools


RSS Feeds and Sharing


Advanced Options


Archives

April 2024
March 2024
February 2024
January 2024
December 2023
November 2023
October 2023
September 2023
August 2023
July 2023
June 2023
May 2023
April 2023
March 2023
February 2023
January 2023
December 2022
November 2022
October 2022
September 2022
August 2022
July 2022
June 2022
May 2022
April 2022
March 2022
February 2022
January 2022
December 2021
November 2021
October 2021
September 2021
August 2021
July 2021
June 2021
May 2021
April 2021
March 2021
February 2021
January 2021
December 2020
November 2020
October 2020
September 2020
August 2020
July 2020
June 2020
May 2020
April 2020
March 2020
February 2020
January 2020
December 2019
November 2019
October 2019
September 2019
August 2019
July 2019
June 2019
May 2019
April 2019
March 2019
February 2019
January 2019
December 2018
November 2018
October 2018
September 2018
August 2018
July 2018
June 2018
May 2018
April 2018
March 2018
February 2018
January 2018
December 2017
November 2017
October 2017
September 2017
August 2017
July 2017
June 2017
May 2017
April 2017
March 2017
February 2017
January 2017
December 2016
November 2016
October 2016
September 2016
August 2016
July 2016
June 2016
May 2016
April 2016
March 2016
February 2016
January 2016
December 2015
November 2015
October 2015
September 2015
August 2015
July 2015
June 2015
May 2015
April 2015
March 2015
February 2015
January 2015
December 2014
November 2014
October 2014
September 2014
August 2014
July 2014
June 2014
May 2014
April 2014
March 2014
February 2014
January 2014
December 2013
November 2013
October 2013
September 2013
August 2013
July 2013
June 2013
May 2013
April 2013
March 2013
February 2013
January 2013
December 2012
November 2012
October 2012
September 2012
August 2012
July 2012
June 2012
May 2012
April 2012
March 2012
February 2012
January 2012
December 2011
November 2011
October 2011
September 2011
August 2011
July 2011
June 2011
May 2011
April 2011
March 2011
February 2011
January 2011
December 2010
November 2010
October 2010
September 2010
August 2010
July 2010
June 2010
May 2010
April 2010
March 2010
February 2010
January 2010
December 2009
November 2009
October 2009
September 2009
August 2009
July 2009
June 2009
May 2009
April 2009
March 2009
February 2009
January 2009
December 2008
November 2008
October 2008
September 2008
August 2008
July 2008
June 2008
May 2008
April 2008
March 2008
February 2008
January 2008
December 2007
November 2007
October 2007
September 2007
August 2007
July 2007
June 2007
May 2007
April 2007
March 2007
February 2007
January 2007


JiscMail is a Jisc service.

View our service policies at https://www.jiscmail.ac.uk/policyandsecurity/ and Jisc's privacy policy at https://www.jisc.ac.uk/website/privacy-notice

For help and support help@jisc.ac.uk

Secured by F-Secure Anti-Virus CataList Email List Search Powered by the LISTSERV Email List Manager