Dear Jacob,
In my hands, different strains of E. coli appear to behave differently
- I found BL21(DE3) needing harder centrifugation than JM109(DE3) to
get a good pellet. And BL21 lysing partially when doing osmotic shock
extraction of a periplasmically expressed protein - while XL1Blue
behaved well.
Although - thinking about the other comment - perhaps I had an
infection with a phage to which BL21 was sensitive but the others not?
Mark
Quoting Jacob Keller <[log in to unmask]>:
> Dear crystallographers,
>
> I recently expressed some new constructs, and found after my usual
> expression protocol that the cell pellets were not compacted at the
> bottom corner of the bottles us usual, but were instead smeared as a
> film on the side, and further, were somewhat clumpy, like clots, and
> with a smaller pellet in the usual location. The centrifugation was
> exactly as usual. I noticed that there was also a bit more foam in the
> medium than usual, but I am not convinced that this was the issue,
> although it might be a symptom. My suspicion is that the constructs are
> lethal and cause cell lysis, but I am not sure. Has anybody seen this
> phenomenon before, and gotten to the bottom of it?
>