JiscMail Logo
Email discussion lists for the UK Education and Research communities

Help for SPM Archives


SPM Archives

SPM Archives


SPM@JISCMAIL.AC.UK


View:

Message:

[

First

|

Previous

|

Next

|

Last

]

By Topic:

[

First

|

Previous

|

Next

|

Last

]

By Author:

[

First

|

Previous

|

Next

|

Last

]

Font:

Proportional Font

LISTSERV Archives

LISTSERV Archives

SPM Home

SPM Home

SPM  May 2009

SPM May 2009

Options

Subscribe or Unsubscribe

Subscribe or Unsubscribe

Log In

Log In

Get Password

Get Password

Subject:

Re: Art_Repair, Art_Global

From:

Marko Wilke <[log in to unmask]>

Reply-To:

Marko Wilke <[log in to unmask]>

Date:

Thu, 14 May 2009 11:10:23 +0200

Content-Type:

text/plain

Parts/Attachments:

Parts/Attachments

text/plain (155 lines)

Hello,

realignment may be related to the sequence used as some vendors offer an 
optional onlein motion correction. The issue then is that motion has 
already (partly) been corrected online during the scan. Some people do 
not like to use it as only the second-to-last scan is used to correct 
the gradient position for the next scan and as the parameters are not 
necessarily written out (they may be in your case, Rachel?). Also, if 
you would like to use unwarping, this may cause trouble as the 
assumptions of the unwarping are not met.

The problem with including SPM's motion parameters is that they also do 
not reflect the true motion in the scanner as some of it has already 
been accounted for. I therefore tend to agree with the reviewer that 
such an approach (using online MoCo but then include SPM's parameters in 
the model) is potentially problematic. Not necessarily, and perhaps not 
even substantially, but potentially. Just my 2 Euro-cents :)

Best,
Marko


Dorian P. schrieb:
> Hi all,
> 
> If the motion parameters are useless, then also realigment is useless.
> I would be curious to hear that reviewer on the topic. How much did
> your subjects move in that experiment Mitchell?
> 
> This is the first time I read that realigment is related to machine
> type. What can be the logic behind that strange reuqest of this
> reviewer?
> 
> Dorian
> 
> 2009/5/14 MITCHELL R.L.C. <[log in to unmask]>:
>> Hello
>>
>> On the subject of movement confounds, a reviewer once insisted that I remove the realignment motion parameters from my model.
>> He/she stated that since I had scanned with a Siemens machine, and taken advantage of the machine's inbuilt/online prospective and retrospective motion correction, that the mp figures were useless.
>>
>> What do people think about this?
>> Does anyone agree or disagree?
>>
>> Best regards
>> Rachel
>>
>> *************************************************************
>>
>> Dr. Rachel L. C. Mitchell,
>> Lecturer in Psychology, Durham University.
>> Honorary Senior Research Fellow, Institute of Psychiatry, KCL.
>> Governor, Tees Esk and Wear Valleys NHS Foundation Trust.
>>
>> Correspondence Address:
>> Dept. of Psychology,
>> Durham University,
>> Science Site,
>> South Road,
>> Durham,
>> Co. Durham.
>> DH1 3LE.
>> U.K.
>>
>> Phone +44 (0)191 334 3272
>> Fax +44 (0)191 334 3241
>>
>>
>> -----Original Message-----
>> From: SPM (Statistical Parametric Mapping) [mailto:[log in to unmask]] On Behalf Of Paul Mazaika
>> Sent: 13 May 2009 18:57
>> To: [log in to unmask]
>> Subject: Re: [SPM] Art_Repair, Art_Global
>>
>> The art_global function tries to automatically detect bad image volumes according
>> to the criteria of unusual global signal, or large scan-to-scan motion,
>> or large total motion from baseline. Use it after realignment, because
>> it uses the rp.txt file. When used just before estimation, it is
>> easier to compare estimation results with and without it, to see if
>> it helps on a particular data set.
>>
>> The clip function marks a volume for repair if the total motion from
>> baseline is > 3mm, which may be useful for short duration artifacts when
>> no motion regressors are used in the design matrix.
>>
>> Handling artifacts is tricky, and the best method may not yet be known.
>> Consequently, the admittedly limited "manual" on the website does not give
>> strong guidance on the best choices of parameters.
>>
>> Note there are alternative (and better documented!) approaches to the artifact
>> problem, including removing volumes by inspection (Luo and Nichols, 2003)
>> or by the art_detect utility (Whitfield-Gabrieli), adding scan null regressors
>> (Lemieux, 2007), and adaptive weighting of the scans (RobustWLS toolbox).
>> Also, motion regressors (e.g. Lund, 2005) are helpful for removing
>> the effect of many artifacts.
>>
>>  -Paul
>>
>>
>>
>> ----- Original Message -----
>> From: "Sanne Boesveldt" <[log in to unmask]>
>> To: [log in to unmask]
>> Sent: Wednesday, May 13, 2009 7:15:12 AM GMT -08:00 US/Canada Pacific
>> Subject: [SPM] Art_Repair, Art_Global
>>
>> Dear all
>>
>> I am trying to use art_repair/art_global in SPM5, but what exactly does
>> Art-global do? And when do I use it, after realignment, or after
>> normalization and smoothing? And what is the function of the 'clip' button
>> in the program?
>>
>> The only manual I could find are the short .txt and .pdf files from
>> http://cibsr.stanford.edu/tools/ArtRepair/ArtRepair.htm, but those don't
>> give that much info unfortunately. Is there a better manual out there?
>>
>> Thanks!
>>
>> Sanne Boesveldt, PhD
>> Postdoctoral Fellow
>> Monell Chemical Senses Center
>> 3500 Market Street
>> Philadelphia, PA 19104
>> USA
>>
>> +1 267 519 4688
>> [log in to unmask]
>>
>> --
>> Paul K. Mazaika, PhD.
>> Center for Interdisciplinary Brain Sciences Research
>> Stanford University School of Medicine
>> Office:  (650)724-6646             Cell:  (650)799-8319
>>
>> CONFIDENTIALITY NOTICE: Information contained in this message and any
>> attachments is intended only for the addressee(s). If you believe
>> that you have received this message in error, please notify the
>> sender immediately by return electronic mail, and please delete it
>> without further review, disclosure, or copying.
>>
> 
> 

-- 
=====================================================================
Marko Wilke                                            (Dr.med./M.D.)
                 [log in to unmask]

Universitäts-Kinderklinik              University Children's Hospital
Abt. III (Neuropädiatrie)             Dept. III (Pediatric neurology)
             Hoppe-Seyler-Str. 1, D - 72076 Tübingen
Tel.: (+49) 07071 29-83416                   Fax: (+49) 07071 29-5473
=====================================================================

Top of Message | Previous Page | Permalink

JiscMail Tools


RSS Feeds and Sharing


Advanced Options


Archives

April 2024
March 2024
February 2024
January 2024
December 2023
November 2023
October 2023
September 2023
August 2023
July 2023
June 2023
May 2023
April 2023
March 2023
February 2023
January 2023
December 2022
November 2022
October 2022
September 2022
August 2022
July 2022
June 2022
May 2022
April 2022
March 2022
February 2022
January 2022
December 2021
November 2021
October 2021
September 2021
August 2021
July 2021
June 2021
May 2021
April 2021
March 2021
February 2021
January 2021
December 2020
November 2020
October 2020
September 2020
August 2020
July 2020
June 2020
May 2020
April 2020
March 2020
February 2020
January 2020
December 2019
November 2019
October 2019
September 2019
August 2019
July 2019
June 2019
May 2019
April 2019
March 2019
February 2019
January 2019
December 2018
November 2018
October 2018
September 2018
August 2018
July 2018
June 2018
May 2018
April 2018
March 2018
February 2018
January 2018
December 2017
November 2017
October 2017
September 2017
August 2017
July 2017
June 2017
May 2017
April 2017
March 2017
February 2017
January 2017
December 2016
November 2016
October 2016
September 2016
August 2016
July 2016
June 2016
May 2016
April 2016
March 2016
February 2016
January 2016
December 2015
November 2015
October 2015
September 2015
August 2015
July 2015
June 2015
May 2015
April 2015
March 2015
February 2015
January 2015
December 2014
November 2014
October 2014
September 2014
August 2014
July 2014
June 2014
May 2014
April 2014
March 2014
February 2014
January 2014
December 2013
November 2013
October 2013
September 2013
August 2013
July 2013
June 2013
May 2013
April 2013
March 2013
February 2013
January 2013
December 2012
November 2012
October 2012
September 2012
August 2012
July 2012
June 2012
May 2012
April 2012
March 2012
February 2012
January 2012
December 2011
November 2011
October 2011
September 2011
August 2011
July 2011
June 2011
May 2011
April 2011
March 2011
February 2011
January 2011
December 2010
November 2010
October 2010
September 2010
August 2010
July 2010
June 2010
May 2010
April 2010
March 2010
February 2010
January 2010
December 2009
November 2009
October 2009
September 2009
August 2009
July 2009
June 2009
May 2009
April 2009
March 2009
February 2009
January 2009
December 2008
November 2008
October 2008
September 2008
August 2008
July 2008
June 2008
May 2008
April 2008
March 2008
February 2008
January 2008
December 2007
November 2007
October 2007
September 2007
August 2007
July 2007
June 2007
May 2007
April 2007
March 2007
February 2007
January 2007
2006
2005
2004
2003
2002
2001
2000
1999
1998


JiscMail is a Jisc service.

View our service policies at https://www.jiscmail.ac.uk/policyandsecurity/ and Jisc's privacy policy at https://www.jisc.ac.uk/website/privacy-notice

For help and support help@jisc.ac.uk

Secured by F-Secure Anti-Virus CataList Email List Search Powered by the LISTSERV Email List Manager