Hi
By default, the min/max intensities (for display) are taken from the
seed mask.
This has been changed now. In the next patch, probtrackx will output
min/max intensities calculated from the fdt_paths.
Cheers,
Saad.
On 19 May 2009, at 17:26, Rachel Hawe wrote:
> Hello,
>
> I am confused about the min and max values for intensities when
> viewing the
> output of probtrack. When tracking from a small seed mask in the
> internal
> capsule, the default in FSLview is 0 to 4, but with other seed masks
> (usually larger) I've seen the upper bound be in the hundreds or even
> thousands. What is the meaning of this intensity range and why does
> it
> differ with the seed mask?
>
> Thanks in advance,
>
> Rachel
>
--
Saad Jbabdi
Oxford University FMRIB Centre
JR Hospital, Headington, OX3 9DU, UK
+44 (0) 1865 222545 (fax 717)
www.fmrib.ox.ac.uk/~saad
|