Hi Andreas,
Andreas Haupt wrote:
> Hi Andrey,
>
> On Wed, 2009-04-01 at 17:19 +0400, Andrey Kiryanov wrote:
>> Hi Andreas,
>>
>> Did you receive my previous mail?
>> Your CE is still flooded with grid_manager_monitor_agent processes. This
>> is caused by bug #48588. You have to restart globus-gatekeeper.
>
> I don't know if this is the case here. What do you mean with "flooded"?
I'm quite sure it is. You have lots of grid_manager_monitor_agent
processes running on your CE while you should have grid_monitor_lite
instead.
> [root@lcg-ce1 ~]# ps auxww|grep grid_manager_monitor_agent | wc -l
> 28
Right, that's exactly what I mean by "flooded". It should be zero.
> [root@lcg-ce1 ~]# ps auxww|grep gma
> patlas36 5717 0.0 1.9 107792 39444 ? R 16:02 0:00 globus-gma: polling job https://lcg-ce1.ifh.de:20021/23015/1238514168/
> root 5722 0.0 0.0 51120 668 pts/0 S+ 16:02 0:00 grep gma
> root 15279 0.9 1.9 106720 40008 ? Ss Mar31 15:49 globus-gma: polling jobs
> patlas01 25746 0.0 0.0 0 0 ? Z 04:02 0:00 [globus-gma] <defunct>
>
> This is ok, isn't it? Well:
It's not really. Gatekeeper needs to be restarted so that GLOBUS_GMA
environment variable gets propagated properly.
> [root@lcg-ce1 ~]# uptime
> 16:05:16 up 231 days, 5:52, 1 user, load average: 3.83, 4.09, 4.67
--
Cheers,
Andrey Kiryanov.
|