Dear all,
When refining a DNA-structure (poor data, resolution 2.5) and using
ARP/wARP Solvent 7.0.1. for water divining with CCP4 6.1.1 and GUI
2.0.4, I get the following error:
QUITTING ... ARP/wARP module stopped with an error message:
ARP_WARP_MODE_WILSON
When checking the "warp_wilson_log" file, I get:
Comments: Overall fit of the data to the Wilson curve:
Comments: Problems Resolution range 5.15 to 4.89
Comments: Problems Resolution range 4.89 to 4.67
Comments: Problems Resolution range 2.89 to 2.84
Comments: Possible reasons - missing overloads
Solvent content 1.00
Computed solvent content is too high - check your input
***** ERROR *****
I was kind of surprised, because with the same data! and an older
version of ARP/wARP, which was integrated in the Refmac5 program, I did
not get any errors of this kind..!?
Is there a way to circumvent this please..?
Many thanks
Kristof Van Hecke
Disclaimer: http://www.kuleuven.be/cwis/email_disclaimer.htm
|