JiscMail Logo
Email discussion lists for the UK Education and Research communities

Help for FSL Archives


FSL Archives

FSL Archives


FSL@JISCMAIL.AC.UK


View:

Message:

[

First

|

Previous

|

Next

|

Last

]

By Topic:

[

First

|

Previous

|

Next

|

Last

]

By Author:

[

First

|

Previous

|

Next

|

Last

]

Font:

Proportional Font

LISTSERV Archives

LISTSERV Archives

FSL Home

FSL Home

FSL  May 2008

FSL May 2008

Options

Subscribe or Unsubscribe

Subscribe or Unsubscribe

Log In

Log In

Get Password

Get Password

Subject:

Re: multiecho T2 image acquisition question

From:

Peter Kochunov <[log in to unmask]>

Reply-To:

FSL - FMRIB's Software Library <[log in to unmask]>

Date:

Mon, 5 May 2008 20:37:19 -0500

Content-Type:

text/plain

Parts/Attachments:

Parts/Attachments

text/plain (128 lines)

Depends on the sequence some deal with that better than others. The 
stimulated echo  contributes to the second echo and then it is being 
refocused with the main echo, the contributions from the stimulated echos 
from the third, and later pulses is going to be smaller since magnetization 
is going to decay, but it can produce an odd-even echo differences you 
observe. And yes, siemens MSE sequence isn't particularly good as far as 
dealing with stimulated echo. For this sort of sequence, I think the most 
robust processing will be to discard the first echo and just fit the rest of 
the data.
pk

----- Original Message ----- 
From: "Scott Kolbe" <[log in to unmask]>
To: <[log in to unmask]>
Sent: Monday, May 05, 2008 8:22 PM
Subject: Re: [FSL] multiecho T2 image acquisition question


> Thanks Peter, Steve and David for the insights.
> One follow-up question, would the stimulated echo effect be expected to 
> dimish in later odd echos? Here is are the intensity values for a voxel in 
> ventriclar CSF which one wouldn't expect to vary much in 132ms:
> 1333
> 1567
> 1487
> 1509
> 1490
> 1479
> 1473
> 1453
>
> As you can see, the odd/even difference is apparent but it is small 
> compared to the difference between the first and second echos. Is it 
> possible that the first refocussing pulse could vary in accuracy to later 
> ones or that the spoiler gradients could vary in magnitude? This sequence 
> was acquired on a 3T Trio TIM if anyone has experience with this kind of 
> imaging on this particular machine.
>
> Thanks again for your time,
> Scott
>
>
> Peter Kochunov wrote:
>> Scott,
>> To be very technical, it is the stimulated echo produced by your second 
>> refocusing pulse, due to less then perfect refocusing, that adds the 
>> extra signal to the even echoes. So, one way to deal with this to fit 
>> your data based on even and then odd echoes and average the results. 
>> There are ways of reducing your stimulated echo, first make sure that you 
>> do use 180 degree pulses for refocusing. You can try changing the 
>> refocusing pulse for an adiabatic. And if you have access to the pulse 
>> sequence you can up the magnitude of the crusher gradients, or even make 
>> them asymmetric.
>> pk
>>
>> ----- Original Message ----- From: "David Lythgoe" 
>> <[log in to unmask]>
>> To: <[log in to unmask]>
>> Sent: Monday, May 05, 2008 8:29 AM
>> Subject: Re: [FSL] multiecho T2 image acquisition question
>>
>>
>>> Hi Scott,
>>>
>>> In multiple spin echoes, errors in the flip angle for the refocusing 
>>> pulses
>>> can lead to reduced signal on odd echoes. These are compensated for to 
>>> some
>>> extent on even echoes.
>>> Even if you get perfect 180 pulses at the centre of your image slices, 
>>> the
>>> slice profile won't be perfectly square, and you will have reduced flip
>>> angle further from the centre of the slice.
>>> Do all your even echoes have higher signal than expected?
>>> Also, remember the T2 for CSF is quite long.
>>>
>>>
>>> Dave
>>>
>>>
>>>
>>> On 5/5/08 10:05, "Scott Kolbe" <[log in to unmask]> wrote:
>>>
>>>> Dear FSL list
>>>> this is a question not directly related to FSL but I am a bit lost for
>>>> an alternative place to ask for advice. I have acquired multiecho T2
>>>> images to study relaxation times in a patient group. i found that for
>>>> the first echo image (13ms) the CSF signal is actually darker than in
>>>> the second echo image (26ms) by about 10%. i have acquired 8 echos and
>>>> for the final echo image (132ms), the CSF signal is only 3% darker than
>>>> for the second echo.
>>>> My question is, does anyone have any idea why the first echo would be
>>>> darker than the second. i had presumed that the earlier the echo is
>>>> collected, the more signal there is. is that true in practice?
>>>>
>>>> thanks in advance
>>>> Scott
>>>>
>>>> ========================
>>>> Scott Kolbe
>>>> Postgraduate Student
>>>> Neuroimaging Group
>>>> Howard Florey Institute &
>>>> Centre for Neuroscience
>>>> University of Melbourne
>>>> VIC, Australia, 3010.
>>>>
>>>> ph:       +61 3 8344 1887
>>>> email:    [log in to unmask]
>>>> website:  http://www.neuroimaging.org.au/index.php?id=383
>>>
>
>
> -- 
> ========================
> Scott Kolbe
> Postgraduate Student
> Neuroimaging Group
> Howard Florey Institute &
> Centre for Neuroscience
> University of Melbourne
> VIC, Australia, 3010.
>
> ph:       +61 3 8344 1887
> email:    [log in to unmask]
> website:  http://www.neuroimaging.org.au/index.php?id=383
> 

Top of Message | Previous Page | Permalink

JiscMail Tools


RSS Feeds and Sharing


Advanced Options


Archives

March 2024
February 2024
January 2024
December 2023
November 2023
October 2023
September 2023
August 2023
July 2023
June 2023
May 2023
April 2023
March 2023
February 2023
January 2023
December 2022
November 2022
October 2022
September 2022
August 2022
July 2022
June 2022
May 2022
April 2022
March 2022
February 2022
January 2022
December 2021
November 2021
October 2021
September 2021
August 2021
July 2021
June 2021
May 2021
April 2021
March 2021
February 2021
January 2021
December 2020
November 2020
October 2020
September 2020
August 2020
July 2020
June 2020
May 2020
April 2020
March 2020
February 2020
January 2020
December 2019
November 2019
October 2019
September 2019
August 2019
July 2019
June 2019
May 2019
April 2019
March 2019
February 2019
January 2019
December 2018
November 2018
October 2018
September 2018
August 2018
July 2018
June 2018
May 2018
April 2018
March 2018
February 2018
January 2018
December 2017
November 2017
October 2017
September 2017
August 2017
July 2017
June 2017
May 2017
April 2017
March 2017
February 2017
January 2017
December 2016
November 2016
October 2016
September 2016
August 2016
July 2016
June 2016
May 2016
April 2016
March 2016
February 2016
January 2016
December 2015
November 2015
October 2015
September 2015
August 2015
July 2015
June 2015
May 2015
April 2015
March 2015
February 2015
January 2015
December 2014
November 2014
October 2014
September 2014
August 2014
July 2014
June 2014
May 2014
April 2014
March 2014
February 2014
January 2014
December 2013
November 2013
October 2013
September 2013
August 2013
July 2013
June 2013
May 2013
April 2013
March 2013
February 2013
January 2013
December 2012
November 2012
October 2012
September 2012
August 2012
July 2012
June 2012
May 2012
April 2012
March 2012
February 2012
January 2012
December 2011
November 2011
October 2011
September 2011
August 2011
July 2011
June 2011
May 2011
April 2011
March 2011
February 2011
January 2011
December 2010
November 2010
October 2010
September 2010
August 2010
July 2010
June 2010
May 2010
April 2010
March 2010
February 2010
January 2010
December 2009
November 2009
October 2009
September 2009
August 2009
July 2009
June 2009
May 2009
April 2009
March 2009
February 2009
January 2009
December 2008
November 2008
October 2008
September 2008
August 2008
July 2008
June 2008
May 2008
April 2008
March 2008
February 2008
January 2008
December 2007
November 2007
October 2007
September 2007
August 2007
July 2007
June 2007
May 2007
April 2007
March 2007
February 2007
January 2007
2006
2005
2004
2003
2002
2001


JiscMail is a Jisc service.

View our service policies at https://www.jiscmail.ac.uk/policyandsecurity/ and Jisc's privacy policy at https://www.jisc.ac.uk/website/privacy-notice

For help and support help@jisc.ac.uk

Secured by F-Secure Anti-Virus CataList Email List Search Powered by the LISTSERV Email List Manager