Hi Marie,
> I checked that out and the project does seem to be pointing to the
> right .xml. I wonder if this wasn't the case more than just the
> import would have gone awry, up until then the project seemed well
> behaved
Seems indeed like it's the import. Are the assignments it is
reverting to ones that originally came from an import as well (i.e.
from CYANA files), or are they ones that you set in Analysis yourself?
If they did come from an original import, it could be that the
FormatConverter is picking up the 'old' information instead of the
new info, and using that to set the assignments.
Before you import, try the following:
1. Open the FormatConverter
2. Go to process->Clean up resonance application data
3. Select cyana, then OK, then YES
4. Repeat 2. and 3. for dyana and xeasy, just in case.
Then do the import.
Hope that works,
Wim
|