Hello Carl,
this is a bit odd, indeed, if you have used the distributed templates
(2x2x2 mm3, MNI space) for segmentation and then did simple VBM on it.
If I understood it correctly, you checked, that after segmentation/modulation
and smoothing your resulting smwc*img files are in alignment with the original
grey, white and CSF template as contained in the /tpm folder - is this
correct?
Maybe check this again with the unsmoothed images to go sure, that not only
orientation
and size are correct, but also AC/PC and matching of the cortical ribbon.
If this is still ok, next check if the resulting beta and con images are in
alignment with the templates.
br,
Philipp