Sorry, I don't know off the top of my head. A colleague did that bit
for us. I shall inquire, but people may have gone for the holidays...
Obviously your Philips contact would be able to tell you. Also,
whilst I haven't used it, there's quite a good electronic manual on
the scanner, I don't know if that has any info in it about this.
Suzanna
On 21 Dec 2007, at 12:15, Diana Tordesillas Gutiérrez wrote:
> Thank you Suzanna for your fast reply, I found the discussion about
> nii
> files. Just one more question, when using the par/rec files, how do
> you
> get the bvecs from the scanner?
>
> Diana
>
>
>
>
>
> Suzanna Laycock dijo:
>> hi,
>>
>> I think there's some info about this in the FSL archives.
>>
>> In our group, we export the files from the scanner in .par and .rec
>> format, then used the fslcreatehd tool to convert to analyse format,
>> but I guess that can be used for nifti as well.
>>
>> Suzanna
>>
>> On 21 Dec 2007, at 11:36, Diana Tordesillas wrote:
>>
>>> Hi,
>>>
>>> Our hospital adquired recently a 3T Philips Achieva and we are
>>> testing
>>> sequences for DTI. I have been importing their dicom images and
>>> transforming
>>> them to nifti using either dcm2nii (MRIcroN) o MRIconvert2.0. I
>>> am not
>>> totally convinced with the files I get and I would appreciate if
>>> people from
>>> another centers with a Philips scanner could tell me wchich method
>>> they use.
>>>
>>> Thanks,
>>>
>>> Diana
>>
|