Hello,
There is an attribute of DataSource called dataType. It is an enumeration
with preset values ('processed', 'FID', 'part-processed') but is "open" so
new values can be added. This is a bit of a kludge which I've never been
perfectly happy with. It seems that in some of Analysis a spectrum is
considered valid only if dataType = 'processed' and in other parts this
condition is not enforced. We should enforce it uniformly. Our guess
(given what you say below) is that your spectra have had this attribute
set to something besides 'processed' (it is a mandatory attribute so it
has to be set to something). We are (now) thinking that perhaps we should
check on start-up if all the dataDims for a given dataSource are of type
FreqDataDim and if so set dataType to be 'processed'.
Wayne
On Thu, 12 Jul 2007, Magnus Lundborg wrote:
> Hello,
>
> I've got a project that wasn't made in Analysis. It doesn't contain any
> processed spectra, but it's got peaks, resonances and assignments in 1D
> 1H and 13C as well as 2D HSQC and TOCSY. When I open this project in
> analysis I end up with four empty windows without any options under the
> spectra tab. If I create a new window, based on e.g. the window
> containing the HSQC, I get the option to make that spectrum visible and
> in that new window all peaks are shown and the spectrum can be
> activated/deactivated. What I can't find is a way to add spectra to
> already existing windows or select which should be shown. How can I do
> that? I've tried to look in all window related dialogs. It feels a bit
> strange to create new windows rather than add things to the existing ones.
>
> Then I also have the problem that the 1D peaks don't show up, but that
> might be because I haven't set a valid value for the peaks when creating
> them so this is probably nothing for you to look into.
>
> Thanks for all help.
>
> /Magnus
>
|