>Did you already try SPM5's DICOM to NIfTI or SPM2's DICOM to Analyze
>converter?
Thanks for your prompt response. We are hesitating in using SPM5's DICOM to
NIfTI, since we're quite comfortable with the Analyze format. I'm wondering
if you could explain us the advantage of NIfTi over the Analyze format, esp
the reason why in NIfTi we don't have to worry about the left and right
issue any more?
Sincerely yours,
Xueying (Sherry) Zhang
--------------------------------------
Ph.D.
Department of Biomedical Engineering
SUNY at Stony Brook
>From: Volkmar Glauche <[log in to unmask]>
>Reply-To: Volkmar Glauche <[log in to unmask]>
>To: [log in to unmask]
>Subject: Re: [SPM] Converting Siemens Mosaic images to 3D analyze images
>Date: Mon, 4 Jun 2007 22:44:09 +0200
>
>Did you already try SPM5's DICOM to NIfTI or SPM2's DICOM to Analyze
>converter?
>
>Zitat von "Xueying (Sherry) Zhang" <[log in to unmask]>:
>
>>Dear SPM users,
>>
>>
>>
>>We're trying to convert Siemens Mosaic images to SPM analyze images. We
>>used
>>MRIconvert before, which unfortunately has our data flipped. We're
>>wondering
>>what other software we can use for the conversion.
>>
>>
>>
>>Thanks!
>>
>>
>>
>>Xueying (Sherry) Zhang
>>
>>
>>
>>Ph.D.
>>
>>LSEC
>>
>>Biomedical Engineering
>>
>>Stony Brook University
>>
>>
>>
>>