Hello,
It sounds like the ccp/Nmr.xml file might have been truncated (due to
either a full disk or network failure or ...). Which is not good. To
check for sure, look at the tail end of ccp/Nmr.xml (e.g. using "tail").
You should see something like:
</_StorageUnit>
<!--End of Memops Data-->
If not then the file has been truncated. If so you will need to go to a
backup. If you have only been doing NMR-related things since the last
successful opening of the project (so not creating new windows, or
creating new molecules, etc.) then you should only need to copy
ccp/Nmr.xml.bak or ccp/Nmr.xml.bac (depending on which is more recent) to
ccp/Nmr.xml (but save a copy of the truncated Nmr.xml somewhere just in
case!). If that does not work (e.g. because other *.xml files have also
been truncated) then you will end up needing to copy more. But let's
start with this and see how you get on.
Wayne
On Mon, 25 Jun 2007, Ratti, J. wrote:
> Hi!
>
> I have a problem openin a project, when i try the following error message appear:
>
>
> project invalis, pease quit, fix and re-start: Error loading file XML
> element <PeakIntensity ID="32939" value="196XML elemnt does not end in
> '>'
>
>
> in the terminal thi appear:
>
> >>> last xml element read:
> <PeakIntensity _ID="_32939" value="196
>
> parser state was:
> reading
>
> ERROR loading xml ccp.nmr.Nmr ccp/Nmr.xml
>
> please help!!!
>
> thank you
>
> joyce
>
|