> if (delta <= tolDict[pd1.dataDim][0] ) or (delta <= tolDict[pd2.dataDim][0]):
>
> so that it's just if they're within the Min/default tolerances?
Changed.
> 2. Memory of settings from invocation to invocation
>
> We see patchy memory of the settings to "Tolerances for shift matching".
> 1H Min/default tolerances do seem to be remembered, but for our 13C 3D
> NOESY the Min/default tolerance gets reset to 0.1 ppm at each reopening of
> the project.
This popup doesn't set the assignment tolerances, which is what the NOE
match tolerances default to. I don't want this popup to interfere with
this value, so I may add a separately remembered tolerance for NOE
matching. However, this is not a quick fix.
> Also the Max PPM tolerrances for all 3 dimensions get set to
> the same value as the Min at each reopening of the project.
The Max value is not used for anything (save the above error) at the
moment so this shouldn't matter.
> 3. Updating w.r.t. changes in User sequence numbering
>
> We also noticed that when we changes the Start Seq for a chain, Shift
> Match Distance constraints did not catch up with the new numbering until
> the whole project was saved & restarted.
I will add an extra notifier to take care of this.
T.
-------------------------------------------------------------------------------
Dr Tim Stevens Email: [log in to unmask]
Department of Biochemistry [log in to unmask]
University of Cambridge Phone: +44 1223 766022 (office)
80 Tennis Court Road +44 7816 338275 (mobile)
Old Addenbrooke's Site +44 1223 364613 (home)
Cambridge CB2 1GA WWWeb: http://www.bio.cam.ac.uk/~tjs23
United Kingdom http://www.pantonia.co.uk
-------------------------------------------------------------------------------