Dear John and SPMers:
I have run get_integrals on 54 smoothed, normalized, modulated, and
segmented gray matter scans in spm2. The global values are listed below.
This script has always produced values between 0 and 1, which is logical
because the intensity value of these images lies between 0 and 1.
As you can see, these values lie between 1 and 10. Is it possible that
the values are off by a decimal place, or are they accurate globals for
these scans?
Rob McClure
6.8187
6.6808
7.9114
7.5617
7.3751
7.3255
8.7109
8.7260
6.6468
6.5391
7.0270
6.8599
7.6839
7.6745
5.9114
5.9194
8.1486
7.9044
8.3151
8.1477
7.0560
7.0159
7.6409
7.6673
8.3394
8.1614
7.3816
7.3207
7.9379
7.7792
7.4306
7.4355
6.9224
6.9282
7.0999
7.0534
7.7512
7.7731
7.3237
7.0115
6.9820
7.0082
8.1035
8.1800
7.5433
7.5983
8.2067
8.2396
6.8189
6.7892
9.4988
9.6953
8.0739
7.4935
Robert K. McClure MD, Assistant Professor
Department of Psychiatry, School of Medicine
University of North Carolina at Chapel Hill
Address: Campus Box #7160
Chapel Hill, NC, 27510-7160, USA
E-mail: [log in to unmask]
Office phone: 919-843-6629
|