Hi
If these volumes are different " by a 180 degree rotation about the
z-axis" do you mean that when viewd inside MEDx you have anterior and
posterior parts swapped? If so, this can be totally unrelated to any
left-right issues. Unless you know the exact specifics of the data
acquisition on your hardware etc the best way is to test your epi
sequency using a phantom or some kind of marker for one of your
subjects - your local MR physicist or radiographer can probably help
you out. If your images are indeed stored in the same conventions as
the MNI template the mis-registration you see is likely to be a result
of >90 degree initial mis-match, see Marks earlier email.
cheers
christian
On 7 Oct 2004, at 02:08, Betty Ann Chodkowski wrote:
> mark,
>
> thank you for your reply.
>
>> The existing fsl release (note that some of this will
>> change in the next release) does not attempt to calculate
>> left-right order anywhere.
>
> okay, good, i understand.
>
> but what i do not understand is why two volumes of the same data with
> the same orientation have different results when registering via FLIRT.
>
> perhaps my belief that these two volumes have the same orientation is
> incorrect. perhaps someone might verify or point out my error in my
> attempts to ascertain the orientation of both volumes. this is what i
> did:
>
> i opened both VolumeA and VolumeB in MEDx as "Raw Generic" after
> defining their volume dimensions. both volumes have the same
> orientation in MEDx. is my interpretation of this correct: since i
> loaded the volumes as "Raw Generic", what i see is what i get, namely,
> they are both of the same orientation *on* *disk*. when i loaded the
> standard volume into MEDx as "Raw Generic", its orientation is
> different
> from my VolumeA and VolumeB by a 180 degree rotation about the z-axis.
> i thought since i avoided the use of the .hdr file in MEDx that "Raw
> Generic" is WYSIWYG.
>
> perhaps i will try to view both volumes through some other display
> mechanism such as matlab (or imageJ?). can anyone recommend a viewer
> (for sun solaris and/or mac os x) i might try to verify the orientation
> of the volumes?
>
> thanks, mark, for your clarification.
>
>> Therefore
>> if all of your images are in the same convention then
>> everything is fine - flirt will *never* flip left and right.
>
> okay, this is reassuring.
>
>> Hope that makes things clearer.
>> I'm not sure whether the problem you have with volumeA vs
>> volumeB is about getting the left-right order correct or
>> just about registering images that are 180 degrees
>> different in initial orientation. Is it the case that
>> your images are 180 degrees different from the standard?
>
> it is the latter case -- my images are 180 degrees different from the
> standard. i can rotate by doing two avwswapdim y -x z. but VolumeA
> registers just fine -- a double avwswapdim would cause the registration
> to fail.
>
> but since i believe VolumeA and VolumeB have a the same orientation (as
> determined by loading the volumes using MEDx's "Raw Generic" format), i
> cannot figure out why VolumeA will register to the standard volume
> whereas VolumeB will not. the resulting html page -- the one with the
> incredibly useful red outline overlay -- shows very clearly that
> VolumeA
> is in the same orientation as standard whereas VolumeB is flipped, ie,
> the subject's nose is pointing in the wrong direction.
>
>> By default flirt only searches +/- 90 degrees from the
>> original orientation, so it is impressive that it actually
>> works for one of the images.
>
> the two volumes are exactly the same data -- just converted from the
> philips scanner format to avw format via two different programs. i
> will
> check via another display package that both volumes are, in fact, in
> the
> same orientation. looking at both conversion programs, there is no
> reorientation of the philips data therefore the data on disk is in the
> same orientation.
>
> a bit frustrating.
>
> i am determined to find the difference, though. i'll let you know when
> i find it.
>
> thanks for your clarifying comments,
> - bettyann
>
>
--
Christian F. Beckmann
Oxford University Centre for Functional
Magnetic Resonance Imaging of the Brain,
John Radcliffe Hospital, Headington, Oxford OX3 9DU, UK
Email: [log in to unmask] - http://www.fmrib.ox.ac.uk/~beckmann/
Phone: +44(0)1865 222782 Fax: +44(0)1865 222717
|