Hi Arun,
Essentially you just want to scale the PE maps, since these are already the
measure of effect size at each voxel in the brain. If you compute the max
- min height of the individual regressor and multiply the PE image by that
number, you'll transform the PE image into a % signal change image. If you
want % signal change copes, then simply add/subtract the transformed PE
files according to your contrasts and you'll get % signal change copes.
Joe
--------------------