Hi Alex,
On Sat, 14 Aug 2004, Alex Fornito wrote:
> Hi all,
> I have axially acquired epis that I'm trying to register to the template
> via coronally acquired T1 structurals (via FLIRT in FEAT) and have a
> couple of questions:
>
> 1 - I'm using a wholehead epi acquired during the same session as the
> initial highres. This is because, although our task epis were supposed to
> be wholehead acquisitions, some of the superior-most slices appear to be
> chopped off. Should I use 3 or 6 DOF?
Assuming that the time series EPI data is a subset of the whlehead epi,
and that there is no chance of rotation between them then DOF=3, i.e,
translation only. However it sounds like you have a reasonable
field-of-view with the time series data, so if there is any rotation, then
DOF=6 should work ok.
> 2 - I've used mricro to change the orientation of the coronal T1
> structural to be the same as the axial epi. However, I've noticed the
> FLIRT FAQ page says the following:
> "Check that the input image looks fine and that the voxel size is correct
> by (a) looking at the images with slices (none of the views should look
> squashed or stretched) and (b) checking the voxel dimensions (pixdim) with
> avwhd (Note: voxel size can be fixed using avwchpixdim)".
> If I view my epis and T1s as they are, the sagittal and cornoal views are
> compressed in the epis, and the axial and sagittal views are compressed in
> the T1s. Does this mean that I need to re-slice the epis and T1s into
> cubic voxels before registering them?
If either of the images looks "compressed" in any axis compared with the
othe axes then that means that your voxel dimensions are wrong - it is
important to fix this in the header before proceeding with registrations.
Cheers, Steve.