Subject:

A new ASHRAE 2003 chapter 21 on Museums , Libraries and Archives is released

From:

Jean Tetreault <[log in to unmask]>

Reply-To:

Indoor Air Quality in Museums and Cultural Heritage Buildings <[log in to unmask]>

Date:

Mon, 6 Oct 2003 15:38:00 -0400

Content-Type:

text/plain

Parts/Attachments:

Parts/Attachments

text/plain (112 lines)

Dear IAQ members,

Lately, a second version of the chapter on Museums, Libraries, and Archives
has been released. Now located in the Chapter 21 of the application book of
ASHRAE.  Cecilcy Grzywacz and James Druzik from the Getty Conservation
Institute, Stefan Michalski and myself from CCI were involved with other
HVAC engineers.

The most important change in the chapter was actually the incorporation of
the issue of airborne pollutants.

Unfortunately, I didn't see the last version of the document before its
publication. After the "fais accomplie" I realized that some texts never
get updated or revised properly. Consequently, the chapter got published
with some amounts of mistakes related to the pollutant sections. The
biggest is probably the explanation of the Table 6 "Air quality targets.."
(which was not written by me). For those who will be interested to get a
copy eventually, you should consider these corrections:

p.21.6.
Tetreaul's (1993) should be replaced by Tetreault's (2003)

p.21.7
Unfortunately, there is no text related to SO2, NOx and Ozone which are
important pollutants in museum indoor env.
p.21.8
Other pollutants in Table 5: it should be Table 2

and the paragraph starting by "Table 6 combines..." should be replaced by:

Table 6 combines pollutant information on object deterioration, troposphere
benchmarks, ambient levels in polluted urban areas or in polluted indoor
environments, and reductions achieved by buildings with and without HVAC
systems. The maximum levels of airborne pollutants allowed in rooms or in
enclosures are based on the approaches of Lowest Observable Adverse Effect
Dose (LOAED) and No Observable Adverse Effect (NOAEL). The concept of NOAEL
is applied only for acetic acid. These approaches have been suggested by
Tétreault (2003) Critical review of detailed in situ observations combined
with laboratory studies has provided a substantial amount of quantitative
information concerning adverse effects of pollutants on materials.
Extensive sets of LOAED and NOAEL are available in Tetreault 2003. Table 6
provides performance targets for the levels of airborne pollutants for most
collections. Hypersensitive materials are excluded from the Table 6 for
common sense reasons. They are just too sensitive to ambient pollutants to
justify their preservation in the room level. The hypersensitive objects
and their respective harmful pollutant are untarnished lead for acetic
acid; silver for hydrogen sulfide; most unfaded sensitive colorants such as
curcumin and alizarin crimson for nitrogen dioxide and ozone; stress
vulcanized natural rubber for ozone and; unfaded sensitive colorants,
newsprint and leather for sulfur dioxide. The reductions noted for
buildings with and without HVAC filtration systems are based on current
experience with buildings, as compiled by Tétreault (2003). This
compilation is based from different authors such as Druzik (1990) and
Nazaroff et al. (1993). The reduction of the Outdoor pollutants' levels by
HVAC without proper filters or simply by natural ventilation can be caused
to low infiltration, low makeup air fast adsorption by indoor materials'
surfaces
(text not edited)

new references related to the new paragraph above:
Druzik, J. R., M. S. Adams, C. Tiller, and G. R. Cass  "The Measurement and
Model Predictions of Indoor Ozone Concentrations in Museums." Atmospheric
Environment 24 (1990), p. 1813 - 1823.

Nazaroff et al. 1993 Airborne Particles in Museums, Research in
Conservation volume 6. p. 22 - 39.

P.21.9
In Table 6 "for performance target of" should be deleted and in Note
"NOEAL" should be "NOAEL"
and in the main text "see Table 4" should be deleted.

For my point of view this sentence is in conflict with Table 6:
" For long-term preservation, levels of airborne pollutants should be below
0.03 :g/m3 or less than 1 :g/m3 for inorganic gases and fine particles and
in the double- or single-digit :g/m3 range for organic carbonyl
pollutants."

P.21.15
In the reference section, the references Tetreault 1993, Tetreault 1999a,
and Tetreault 2001 should be deleted.


This ASHRAE Chapter 21 is available in pdf file:
http://resourcecenter.ashrae.org/store/ashrae/newstore.cgi?itemid=16997&view=item&categoryid=456&page=1&loginid=416005

My book in Airborne Pollutants in Museums, Galleries and Archives: Risk
Assessment, Control Strategies and Preservation Management, Canadian
Conservation Institute. Ottawa (2003) will be released in early January
2004. The delay is due to the French version (not done by me). The English
version is already edited and formatted as seen at the latest IAQ
Conference in  Norwich. It contains the rational of Table 6 of ASHRAE
chapter 21 (without mistake) and specifications for dust and gas filters
adapted for museums needs.

By the mean time, you are invited to read my latest papers on Guidelines
for Pollutant Concentrations in Museums at this link below:
http://www.cci-icc.gc.ca/whats-new/news31/pollutants_e.shtml


Jean Tétreault
Senior Conservation Scientist/ Part Time Acting Manager of the Preventive
Conservation Section
Canadian Conservation Institute
1030 Innes Road Ottawa, Ont. K1A 0M5, Canada
email: [log in to unmask]


Internet sites:
CCI Web: http://www.cci-icc.gc.ca/
Indoor Air Quality in Museums and Archives: http://iaq.dk/

Top of Message | Previous Page | Permalink

JiscMail Tools


RSS Feeds and Sharing


Advanced Options


Archives

April 2024
March 2023
March 2022
April 2021
February 2021
November 2020
September 2020
April 2020
November 2019
September 2019
July 2019
April 2019
November 2018
September 2018
July 2018
December 2017
April 2017
March 2017
February 2017
June 2016
May 2016
April 2016
March 2016
February 2016
January 2016
October 2015
September 2015
August 2015
July 2015
June 2015
May 2015
February 2014
October 2013
August 2013
June 2013
March 2013
May 2012
April 2012
January 2012
December 2011
September 2011
August 2011
June 2011
January 2011
October 2010
August 2010
May 2010
January 2010
October 2009
September 2009
July 2009
June 2009
January 2009
August 2008
March 2008
January 2008
November 2007
September 2007
August 2007
July 2007
April 2007
March 2007
January 2007
2006
2005
2004
2003
2002
2001


JiscMail is a Jisc service.

View our service policies at https://www.jiscmail.ac.uk/policyandsecurity/ and Jisc's privacy policy at https://www.jisc.ac.uk/website/privacy-notice

For help and support help@jisc.ac.uk

Secured by F-Secure Anti-Virus CataList Email List Search Powered by the LISTSERV Email List Manager