Hi:
I tried the following experiment :
A.- I used the Basic shape Square option when defining EV1 under the Full model setup with 30 s off/25 on, TR=2.5 , 100 volumes.
B.- Then I used the Custom (1 entry per volume) Basic shape option. The file I used in this case
was the "same" as the oneyou might get from the Square option; I generated a text file of 1's and -1's
to emulate the on/off conditions. I kept everything else the same (i.e. the Advanced options).
My thought was that the resulting models under A and B should be the same, but they weren't.
Do you know why?
Thanks
lino
|