Dear all
I have a question concerning the image conversion of individual virtual
EEG channels (time-frequency data)
The data were imported from fieldtrip with the spm_eeg_ft2spm routine
Presumably since the labels are arbitrary (and only 4 channels) SPM did
not assign a channel type, meaning that the image conversion routine
does not recognize these channels.
How can I force it to assign the type 'MEEG' / manipulate the
data-structure in such a way that they can be treated that way?
I also had problems converting an EEG raw data set (from BrainVision
*.eeg file) - this gets stuck in ft_senstype (even when converting from
raw format)
Our cap was custom-made and therefore has arbitrary channel names (from
1 to 128), apparently SPM cant deal with that situation ???
thanks
Markus
|